<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Lightning Protection Zone &#8211; Prosurge</title>
	<atom:link href="https://prosurge.com/tag/lightning-protection-zone/feed/" rel="self" type="application/rss+xml" />
	<link>https://prosurge.com</link>
	<description>Maximum Safety in Surge Protection</description>
	<lastBuildDate>Mon, 09 Dec 2024 03:01:47 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>
	<item>
		<title>Lightning protection and grounding knowledge popularization, take you to understand clearly in 2 minutes!</title>
		<link>https://prosurge.com/lightning-protection-and-grounding-knowledge-popularization-take-you-to-understand-clearly-in-2-minutes/</link>
		
		<dc:creator><![CDATA[prosurge]]></dc:creator>
		<pubDate>Thu, 05 Dec 2024 01:39:15 +0000</pubDate>
				<category><![CDATA[Surge Protection Education]]></category>
		<category><![CDATA[Lightning Protection Zone]]></category>
		<category><![CDATA[SPD]]></category>
		<guid isPermaLink="false">https://prosurge.com/?p=18364</guid>

					<description><![CDATA[The grounding of lightning protection devices to prevent lightning overvoltage is usually referred to as lightning protection grounding. Lightning protection devices must have good grounding in order to effectively limit atmospheric overvoltage and scattered lightning currents. Below, the editor will popularize lightning protection and grounding knowledge for you, hoping to be helpful to you!  [...]]]></description>
										<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-1"><p>The grounding of lightning protection devices to prevent lightning overvoltage is usually referred to as lightning protection grounding. Lightning protection devices must have good grounding in order to effectively limit atmospheric overvoltage and scattered lightning currents. Below, the editor will popularize lightning protection and grounding knowledge for you, hoping to be helpful to you!</p>
<p>Lightning protection grounding map:</p>
</div><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-1 hover-type-none"><img fetchpriority="high" decoding="async" width="553" height="434" title="lightning grounding" src="https://prosurge.com/wp-content/uploads/2024/12/lightning-grounding.jpg" alt class="img-responsive wp-image-18365" srcset="https://prosurge.com/wp-content/uploads/2024/12/lightning-grounding-200x157.jpg 200w, https://prosurge.com/wp-content/uploads/2024/12/lightning-grounding-400x314.jpg 400w, https://prosurge.com/wp-content/uploads/2024/12/lightning-grounding.jpg 553w" sizes="(max-width: 800px) 100vw, 553px" /></span></div></div><div class="fusion-text fusion-text-2"><p>The lightning protection device consists of three parts: the lightning arrester (also known as the lightning receiving device. It is a metal rod that directly or indirectly receives lightning, such as lightning rods, lightning strips or lightning nets, as well as overhead ground wires), the down conductor (also known as the grounding wire. It is a metal conductor used to connect the lightning arrester to the grounding device), and the grounding device. The materials used for lightning protection devices should have sufficient mechanical strength and also meet the requirements of corrosion resistance.</p>
<p>In general, the material specifications selected according to these two principles can meet the requirements of dynamic stability and thermal stability when passing through lightning current. The so-called dynamic stability refers to the ability to resist the mechanical damage caused by lightning currents; The so-called thermal stability refers to the ability to resist the thermal damage caused by lightning currents.</p>
<p>Lightning protection grounding is a grounding method that quickly introduces lightning current into the ground to prevent lightning damage. The type and structure of its grounding device are no different from the working or safety grounding of general electrical equipment. The difference is that lightning protection grounding is conducted to discharge lightning into the ground, while working or safety grounding is conducted to discharge power frequency short-circuit current into the ground.</p>
<p>The power frequency short-circuit current is much smaller than the lightning current, and the voltage drop generated when passing through the grounding device is not significant, so there will be no rebound phenomenon. When lightning current flows through the grounding device, the voltage drop is often much higher, which can cause backlash against certain insulation weaknesses or gaps (when lightning waves flow along the independent lightning rod grounding lead and grounding body to the ground, high voltage will be generated due to the inductance of the lead and the grounding resistance of the grounding body. If the protected object is not sufficiently far away from its grounding device in the air, this high voltage will cause backlash discharge on the protected object).</p>
<p>Due to the severe rebound phenomenon of lightning rods and lightning wires, independent grounding devices need to be installed for them. The conduction and leakage current of lightning arresters and discharge gaps are generally within the lightning resistance level of electrical insulation, and are unlikely to cause counterattacks. Therefore, they can be used in conjunction with general electrical equipment or safety grounding devices without the need for separate installation. In addition, when overhead power lines are directly struck by lightning or lightning strikes occur near the lines, induced overvoltages of up to several hundred kilovolts will be formed on the lines and transmitted into buildings along the two ends of the lines. This phenomenon is called high potential introduction. To prevent high potential from causing injury, a grounding device is also required.</p>
</div><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-2 hover-type-none"><img decoding="async" width="679" height="415" title="LPS lightning" src="https://prosurge.com/wp-content/uploads/2024/12/LPS-lightning.jpg" alt class="img-responsive wp-image-18367" srcset="https://prosurge.com/wp-content/uploads/2024/12/LPS-lightning-200x122.jpg 200w, https://prosurge.com/wp-content/uploads/2024/12/LPS-lightning-400x244.jpg 400w, https://prosurge.com/wp-content/uploads/2024/12/LPS-lightning-600x367.jpg 600w, https://prosurge.com/wp-content/uploads/2024/12/LPS-lightning.jpg 679w" sizes="(max-width: 800px) 100vw, 679px" /></span></div></div><div class="fusion-clearfix"></div></div></div></div></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Introduction to Lightning Protection Zone (LPZ)</title>
		<link>https://prosurge.com/introduction-to-lightning-protection-zone-lpz/</link>
		
		<dc:creator><![CDATA[prosurge]]></dc:creator>
		<pubDate>Fri, 19 Apr 2019 02:42:31 +0000</pubDate>
				<category><![CDATA[Surge Protection Education]]></category>
		<category><![CDATA[Lightning Protection Zone]]></category>
		<category><![CDATA[LPZ]]></category>
		<guid isPermaLink="false">http://prosurge.com/?p=16021</guid>

					<description><![CDATA[Lightning Protection Zone (LPZ) In IEC standard, terms like type 1/2/3 or class 1/2/3 surge protective device is very popular. In this article, we are going to introduce a concept that is highly related to the previous terms: lightning protection zone or LPZ. What is lightning protection zone and why does it matters? The  [...]]]></description>
										<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box fusion-builder-row-2 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-3"><p><span style="color: #e02828;"><strong>Lightning Protection Zone (LPZ)</strong></span></p>
<p>In IEC standard, terms like type 1/2/3 or class 1/2/3 surge protective device is very popular. In this article, we are going to introduce a concept that is highly related to the previous terms: lightning protection zone or LPZ.</p>
<p>What is lightning protection zone and why does it matters?</p>
<p>The lightning protection zone concept is originated and described in the IEC 62305-4 standard which is an international stand for lightning protection. The LPZ concept is based on the idea of gradually reducing lightning energy to a safe level so that it won&#8217;t cause damage to terminal device.</p>
<p>Let&#8217;s see a basic illustration.</p>
</div><div class="fusion-image-element in-legacy-container" style="--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><span class=" fusion-imageframe imageframe-none imageframe-3 hover-type-none"><img decoding="async" width="900" height="428" alt="Lightning Protection Zone Illustration-Prosurge-900" title="Lightning Protection Zone Illustration-Prosurge-900" src="http://prosurge.com/wp-content/uploads/2019/04/Lightning-Protection-Zone-Illustration-Prosurge-900.jpg" class="img-responsive wp-image-16022" srcset="https://prosurge.com/wp-content/uploads/2019/04/Lightning-Protection-Zone-Illustration-Prosurge-900-200x95.jpg 200w, https://prosurge.com/wp-content/uploads/2019/04/Lightning-Protection-Zone-Illustration-Prosurge-900-400x190.jpg 400w, https://prosurge.com/wp-content/uploads/2019/04/Lightning-Protection-Zone-Illustration-Prosurge-900-600x285.jpg 600w, https://prosurge.com/wp-content/uploads/2019/04/Lightning-Protection-Zone-Illustration-Prosurge-900-800x380.jpg 800w, https://prosurge.com/wp-content/uploads/2019/04/Lightning-Protection-Zone-Illustration-Prosurge-900.jpg 900w" sizes="(max-width: 800px) 100vw, 900px" /></span></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:15px;margin-bottom:15px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-4"><p><span style="color: #d91e1e;"><strong>So what does the different lightning protection zone means?</strong></span></p>
<p>LPZ 0A: It is a unprotected zone outside the building and it&#8217;s exposed to direct lightning strike. In LPZ 0A, there is no shielding against electromagnetic interference pulses LEMP (Lightning Electromagnetic Pulse).</p>
<p>LPZ 0B: Like LPZ 0A, it is also outside the building yet LPZ 0B are protected by the external lightning protection system, normally within the protection area of the lightning rod. Again, there is no shielding against LEMP too.</p>
<p>LPZ 1: It is the zone inside the building. At this zone, it is possible there are partial lightning current exists. But the lightning current is quite low as at least half of it are conducted to the ground by external lightning protection system. Between LPZ0B and LPZ1, there should be Class 1/ Type 1 SPD installed to protect the downstream devices.</p>
<p>LPZ2: It is also the zone Zone inside the building where low surges are possible. Between LPZ2 and LPZ1, there should be Class 2/Type2 Surge protection device.</p>
<p>LPZ3: Like LPZ1&amp;2, LPZ3 is also the zone inside the building where there is no or minimal surge currents.</p>