<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>surge protection device &#8211; Prosurge</title>
	<atom:link href="https://prosurge.com/tag/surge-protection-device/feed/" rel="self" type="application/rss+xml" />
	<link>https://prosurge.com</link>
	<description>Maximum Safety in Surge Protection</description>
	<lastBuildDate>Mon, 14 Mar 2022 01:25:56 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>
	<item>
		<title>Prosurge passed the re-examination prodecure on its Surge Protective Device (SPD) and granted to continuously bear the KEMA-KEUR certification mark</title>
		<link>https://prosurge.com/prosurge-passed-the-re-examination-prodecure-on-its-surge-protective-device-spd-and-granted-to-contiuous-bear-the-kema-keur-certification-mark/</link>
		
		<dc:creator><![CDATA[prosurge]]></dc:creator>
		<pubDate>Mon, 08 Mar 2021 03:58:42 +0000</pubDate>
				<category><![CDATA[News]]></category>
		<category><![CDATA[KEMA surge protective device]]></category>
		<category><![CDATA[surge protection device]]></category>
		<guid isPermaLink="false">https://prosurge.com/?p=17085</guid>

					<description><![CDATA[Congrats! In Mar 04, 2021, Prosurge passed the re-examination prodecure on its Surge Protective Device (SPD) from DEKRA Certification B.V. and granted to continuously bear the KEMA-KEUR certification mark. DEKRA Certification B.V. has its Head office at Arnhem, The Netherlands, with the Registration number: C 001 and can apply tests to the SPDs  [...]]]></description>
										<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy"><div class="fusion-image-element in-legacy-container" style="--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><span class=" fusion-imageframe imageframe-none imageframe-1 hover-type-none"><img decoding="async" width="300" height="100" title="KEMA-KEUR certification mark, IEC61643-11" src="https://prosurge.com/wp-content/uploads/2021/03/KEMA-KEUR-certification-mark-IEC61643-11-300x100.jpg" alt class="img-responsive wp-image-17087" srcset="https://prosurge.com/wp-content/uploads/2021/03/KEMA-KEUR-certification-mark-IEC61643-11-200x67.jpg 200w, https://prosurge.com/wp-content/uploads/2021/03/KEMA-KEUR-certification-mark-IEC61643-11-400x133.jpg 400w, https://prosurge.com/wp-content/uploads/2021/03/KEMA-KEUR-certification-mark-IEC61643-11-600x200.jpg 600w, https://prosurge.com/wp-content/uploads/2021/03/KEMA-KEUR-certification-mark-IEC61643-11-800x266.jpg 800w, https://prosurge.com/wp-content/uploads/2021/03/KEMA-KEUR-certification-mark-IEC61643-11-1200x399.jpg 1200w, https://prosurge.com/wp-content/uploads/2021/03/KEMA-KEUR-certification-mark-IEC61643-11.jpg 1317w" sizes="(max-width: 800px) 100vw, 600px" /></span></div><div class="fusion-image-element in-legacy-container" style="--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><span class=" fusion-imageframe imageframe-none imageframe-2 hover-type-none"><img fetchpriority="high" decoding="async" width="300" height="284" title="KEMA SPD 3+1 SPD SP275 3PN-S" src="https://prosurge.com/wp-content/uploads/2021/03/KEMA-SPD-31-SPD-SP275-3PN-S-300x284.jpg" alt class="img-responsive wp-image-17089" srcset="https://prosurge.com/wp-content/uploads/2021/03/KEMA-SPD-31-SPD-SP275-3PN-S-200x190.jpg 200w, https://prosurge.com/wp-content/uploads/2021/03/KEMA-SPD-31-SPD-SP275-3PN-S-400x379.jpg 400w, https://prosurge.com/wp-content/uploads/2021/03/KEMA-SPD-31-SPD-SP275-3PN-S-600x569.jpg 600w, https://prosurge.com/wp-content/uploads/2021/03/KEMA-SPD-31-SPD-SP275-3PN-S-800x759.jpg 800w, https://prosurge.com/wp-content/uploads/2021/03/KEMA-SPD-31-SPD-SP275-3PN-S-1200x1138.jpg 1200w, https://prosurge.com/wp-content/uploads/2021/03/KEMA-SPD-31-SPD-SP275-3PN-S.jpg 1662w" sizes="(max-width: 800px) 100vw, 600px" /></span></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-1"><p>Congrats!</p>
<p>In Mar 04, 2021, Prosurge passed the re-examination prodecure on its Surge Protective Device (SPD) from DEKRA Certification B.V. and granted to continuously bear the KEMA-KEUR certification mark.</p>
<p>DEKRA Certification B.V. has its Head office at Arnhem, The Netherlands, with the Registration number: C 001 and can apply tests to the SPDs as per EN ISO/IEC 17065:2012.</p>
<p>Prosurge SPD is with global patented thermal disconnector design and arc extinguishing device (TPAE technology), fail-safe and self-protected. It design with thermal protection to open in the event of overheating due to an abnormal over-voltage or temporary over voltage (TOV) and will interrupt any abnormal current that may be encountered.</p>
<p>This KEMA-KEUR SPD also UL listed as Type 1 SPD per UL1449-4th.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-2"><p>Congrats!</p>
<p>In Mar 04, 2021, Prosurge passed the re-examination prodecure on its Surge Protective Device (SPD) from DEKRA Certification B.V. and granted to continuously bear the KEMA-KEUR certification mark.</p>
<p>DEKRA Certification B.V. has its Head office at Arnhem, The Netherlands, with the Registration number: C 001 and can apply tests to the SPDs as per EN ISO/IEC 17065:2012.</p>
<p>Prosurge SPD is with global patented thermal disconnector design and arc extinguishing device (TPAE technology), fail-safe and self-protected. It design with thermal protection to open in the event of overheating due to an abnormal over-voltage or temporary over voltage (TOV) and will interrupt any abnormal current that may be encountered.</p>
<p>This KEMA-KEUR SPD also UL listed as Type 1 SPD per UL1449-4th.</p>
</div><div class="fusion-clearfix"></div></div></div></div></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Prosurge Has New Surge Protection Project in Maldives</title>
		<link>https://prosurge.com/prosurge-has-new-surge-protection-project-in-maldives/</link>
		
		<dc:creator><![CDATA[prosurge]]></dc:creator>
		<pubDate>Thu, 18 Jul 2019 06:25:54 +0000</pubDate>
				<category><![CDATA[News]]></category>
		<category><![CDATA[Projects]]></category>
		<category><![CDATA[Prosurge]]></category>
		<category><![CDATA[surge protection device]]></category>
		<category><![CDATA[surge protection project]]></category>
		<guid isPermaLink="false">http://prosurge.com/?p=16208</guid>

					<description><![CDATA[Prosurge has a new surge protection projects in Maldives, one of the most beautiful island country in South Asia. The SPD installed is our MDSS series which customer used to protect the devices and fire alarm control panels inside the building.]]></description>
										<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box fusion-builder-row-2 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-3 hover-type-none"><img decoding="async" width="1280" height="957" alt="Prosurge Has New Surge Protection Project in Maldives" title="Prosurge Has New Surge Protection Project in Maldives" src="http://prosurge.com/wp-content/uploads/2019/07/Prosurge-Has-New-Surge-Protection-Project-in-Maldives.jpg" class="img-responsive wp-image-16210" srcset="https://prosurge.com/wp-content/uploads/2019/07/Prosurge-Has-New-Surge-Protection-Project-in-Maldives-200x150.jpg 200w, https://prosurge.com/wp-content/uploads/2019/07/Prosurge-Has-New-Surge-Protection-Project-in-Maldives-400x299.jpg 400w, https://prosurge.com/wp-content/uploads/2019/07/Prosurge-Has-New-Surge-Protection-Project-in-Maldives-600x449.jpg 600w, https://prosurge.com/wp-content/uploads/2019/07/Prosurge-Has-New-Surge-Protection-Project-in-Maldives-800x598.jpg 800w, https://prosurge.com/wp-content/uploads/2019/07/Prosurge-Has-New-Surge-Protection-Project-in-Maldives-1200x897.jpg 1200w, https://prosurge.com/wp-content/uploads/2019/07/Prosurge-Has-New-Surge-Protection-Project-in-Maldives.jpg 1280w" sizes="(max-width: 800px) 100vw, 1200px" /></span></div></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:15px;margin-bottom:15px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-3"><p>Prosurge has a new surge protection projects in Maldives, one of the most beautiful island country in South Asia. The SPD installed is our MDSS series which customer used to protect the devices and fire alarm control panels inside the building.</p>
</div><div class="fusion-clearfix"></div></div></div></div></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Surge Protection Device: The Most Comprehensive Introduction</title>
		<link>https://prosurge.com/surge-protection-device/</link>
		
		<dc:creator><![CDATA[prosurge]]></dc:creator>
		<pubDate>Thu, 14 Mar 2019 08:43:52 +0000</pubDate>
				<category><![CDATA[Surge Protection Education]]></category>
		<category><![CDATA[surge protection device]]></category>
		<guid isPermaLink="false">http://prosurge.com/?p=15727</guid>

					<description><![CDATA[Surge Protection Device Surge protection device (or abbreviated as SPD) is not a product that known to the public. The public do know that power quality is a big problem in our society in which more and more sensitive electronics or electrical products are been used. They know about UPS which can provide uninterrupted  [...]]]></description>
										<content:encoded><![CDATA[<p><div class="fusion-fullwidth fullwidth-box fusion-builder-row-3 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-4"><h1><span style="color: #e02424;">Surge Protection Device</span></h1>
<p>Surge protection device (or abbreviated as SPD) is not a product that known to the public. The public do know that power quality is a big problem in our society in which more and more sensitive electronics or electrical products are been used. They know about UPS which can provide uninterrupted power supply. They know voltage stabilizer which, as its name suggest, stabilize or regulate the voltage. Yet most people, enjoying the safety that surge protection device brings, don&#8217;t even realize its existence.</p>
<p>We&#8217;ve been told since childhood that plug off all electrical appliance during thunderstorm otherwise the lightning current may travel inside the building and damage the electrical products.</p>
<p>Well, lightning is indeed very dangerous and harmful. Here is some pictures showing its destruction.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-4 hover-type-none"><img decoding="async" width="600" height="372" alt="Lightning and Surge Damage to Office_600" title="Lightning and Surge Damage to Office_600" src="http://prosurge.com/wp-content/uploads/2019/03/Lightning-and-Surge-Damage-to-Office_600.jpg" class="img-responsive wp-image-15734" srcset="https://prosurge.com/wp-content/uploads/2019/03/Lightning-and-Surge-Damage-to-Office_600-200x124.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/Lightning-and-Surge-Damage-to-Office_600-400x248.jpg 400w, https://prosurge.com/wp-content/uploads/2019/03/Lightning-and-Surge-Damage-to-Office_600.jpg 600w" sizes="(max-width: 800px) 100vw, 600px" /></span></div></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-5 hover-type-none"><img decoding="async" width="600" height="372" alt="Lightning Damage-600_372" title="Lightning Damage-600_372" src="http://prosurge.com/wp-content/uploads/2019/03/Lightning-Damage-600_372.jpg" class="img-responsive wp-image-15741" srcset="https://prosurge.com/wp-content/uploads/2019/03/Lightning-Damage-600_372-200x124.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/Lightning-Damage-600_372-400x248.jpg 400w, https://prosurge.com/wp-content/uploads/2019/03/Lightning-Damage-600_372.jpg 600w" sizes="(max-width: 800px) 100vw, 600px" /></span></div></div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-4 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-8 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:15px;margin-bottom:15px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-5"><p><span style="color: #de1f1f;"><strong>Index of this presentation</strong></span></p>
<p>Well, this is about lightning. How does lightning related to the product surge protection device? In this article, we will give a thorough presentation on this topic. We are going to introduce:</p>
<p><strong>Lightning Protection VS Surge Protection: Related yet Different </strong></p>
<p><strong>Surge </strong></p>
<ul>
<li>What is surge</li>
<li>What cause surge</li>
<li>The effects of surge</li>
</ul>
<p><strong>Surge Protective Device (SPD)</strong></p>
<ul>
<li>Definition</li>
<li>Function</li>
<li>Applications</li>
<li>Components: GDT, MOV, TVS</li>
<li>Classification</li>
<li>Key Parameters</li>
<li>Installation</li>
<li>Standards</li>
</ul>
</div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-5 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-9 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-6"><p><span style="color: #e02626;"><strong>Introduction</strong></span></p>
<p>This article assumes that the reader has no background knowledge in surge protection. Some of the contents are simplified for the sake of easy understanding. We tried to transfer the technical expression into our daily language yet at the same time, it is inevitable that we&#8217;ll lose some accuracy.</p>
<p>And in this presentation, we adopt some surge protection educational material released by various lightning / surge protection companies which we obtained from public source. Herein we thank them for their efforts in educating the public. Should any material is in dispute, please contact us.</p>
<p>Another important note is that lightning protection and surge protection is still not a precise science. For example, we know that lightning likes to hit the tall and pointed objects. That&#8217;s why we use lightning rod to attract lightning and shunt its current to the ground. Yet this is a tendency based on probability, not a rule. In many cases, lightning hit other objects although there is a tall and pointed lightning rod nearby. For an example, ESE (Early Streamer Emission) is considered to be a updated form of lightning rod and thus should have better performance. Yet, it is a very controversial product which many experts believe and approve that it has no advantages over a simple lightning rod. As in surge protection, the dispute is even bigger. IEC standard, which is mainly proposed and drafted by European experts, define the waveform of direct lightning as 10/350 μs impulse which UL standard, mainly proposed and drafted by American experts, do not recognize such waveform.</p>
<p>From our perspective, our understanding of  lightning will become more and more precise and accurate eventually as we do more research on this field. For example, all of the surge protection products nowadays are developed based on the theory that lightning current is single waveform impulse. Yet some SPDs that can pass all the tests inside the lab still fail on the field when lightning actually hits. Thus recent years, more and more experts believe that lightning current is a multiple waveforms impulse. This is advancement and surely will improve the performance of surge protection devices that developed based on that.</p>
<p>Yet in this article, we are going to dig into the controversial topics. We try to give a elementary yet thorough, comprehensive overall introduction of surge protection and surge protection device. So, let&#8217;s begin.</p>
</div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-6 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-10 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-7"><p><span style="color: #de2323;"><strong>1. Lightning Protection VS Surge Protection</strong></span></p>
<p>You may ask why do we need to know anything about lightning protection when we talk about surge protection. Well, this two concepts are closely related as many surges are actually caused by lightning. We talk more about the cause of surges in the next chapter. Some theories believe that surge protection is part of lightning protection. These theories believe that lightning protection can be divided into two parts: external lightning protection whose main product is lightning rod (air terminal), down conductor and earthing material and internal lightning protection whose major product is surge protection device, either for AC/DC power supply or for data/signal line.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-11 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-8"><p>One of the strong advocate of this classification is ABB. In this video, ABB (Furse is an ABB company) give a very thorough presentation of the lightning protection in their opinions. For the lightning protection of a typical building, there should be external protection to shunt the lightning current to the ground and internal protection to prevent power supply and data/signal line from damage. And in this video, ABB believes that air terminal/conductors/earthing material are products mainly for direct lightning hit and surge protection device are mainly for protection of indirectly lightning (a nearby lightning).</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-12 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-video fusion-youtube" style="--awb-max-width:600px;--awb-max-height:360px;"><div class="video-shortcode"><div class="fluid-width-video-wrapper" style="padding-top:60%;" ><iframe title="YouTube video player 1" src="https://www.youtube.com/embed/tmg9EedjELA?wmode=transparent&autoplay=0" width="600" height="360" allowfullscreen allow="autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture;"></iframe></div></div></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-13 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-9"><p>Another Theory try to contain lightning protection within the range of external protection. One of the reason the make such distinction is that the former classification may mislead the public to think that surge is solely caused by lightning which is far from truth. Based on statistics, only 20% of surge are caused by lightning and 80% of surges are caused by factor inside the building. You can see that in this lightning protection video, it mention nothing about surge protection.</p>
</div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-image-element in-legacy-container" style="--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><span class=" fusion-imageframe imageframe-none imageframe-6 hover-type-none"><a class="fusion-no-lightbox" href="What Cause Surge" target="_self" aria-label="What Cause Surge_600"><img decoding="async" width="600" height="245" src="http://prosurge.com/wp-content/uploads/2019/03/What-Cause-Surge_600.jpg" alt class="img-responsive wp-image-15748" srcset="https://prosurge.com/wp-content/uploads/2019/03/What-Cause-Surge_600-200x82.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/What-Cause-Surge_600-400x163.jpg 400w, https://prosurge.com/wp-content/uploads/2019/03/What-Cause-Surge_600.jpg 600w" sizes="(max-width: 800px) 100vw, 600px" /></a></span></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-14 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-video fusion-youtube" style="--awb-max-width:600px;--awb-max-height:360px;"><div class="video-shortcode"><div class="fluid-width-video-wrapper" style="padding-top:60%;" ><iframe title="YouTube video player 2" src="https://www.youtube.com/embed/SGTUekOsTns?wmode=transparent&autoplay=0" width="600" height="360" allowfullscreen allow="autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture;"></iframe></div></div></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-15 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-10"><p>Lightning protection is a complicated system involving many different products. Surge protection is only part of a coordinated lightning protection system. For common consumers, it is not necessary to dig into the academic discussion. After all, like we say, lightning protection is still not a precise science. So for us, this may not be a 100% recognized yet easy way to understand lightning protection and its relationship with surge protection device.</p>
</div><div class="fusion-text fusion-text-11"><h3 style="text-align: center;">Lightning Protection</h3>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-16 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-padding-left:320px;--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-12"><p><strong>External Lightning Protection </strong></p>
<ul>
<li>Air Terminal</li>
<li>Conductor</li>
<li>Earthing</li>
<li>External Shielding</li>
</ul>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-17 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-padding-right:250px;--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-13"><p><strong>Internal Lightning Protection </strong></p>
<ul>
<li>Internal Shielding</li>
<li>Equipotential Bonding</li>
<li><span style="color: #e02626;">Surge Protection Device</span></li>
</ul>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-18 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-14"><p>Before we finish this session, we are going to introduce the last concept: <strong>lightning stroke density</strong>. Basically it means how frequent the lightning stroke is in a certain area. On the right is a lightning stroke density map of the world.</p>
<p>Why is lightning stroke density important?</p>
<ul>
<li>From sales and marketing point, area with high lightning density have stronger needs for lightning and surge protection.</li>
<li>From technical point, an SPD installed on high lightning hit area should have bigger surge current capacity. A 50kA SPD may survive 5 years in Europe but only survive 1 year in Philippines.</li>
</ul>
<p>Prosurge&#8217;s major markets are North America, South America and Asia. As we can see on this map, these markets are all fall within high lightning stroke density area. <strong>This is a strong evidence that our surge protection device is of premium quality and thus can survive in areas with most frequent lightning strokes. </strong>Click and check some of our surge protection projects around the world.</p>
</div><ul style="--awb-size:13px;--awb-iconcolor:#f44336;--awb-line-height:22.1px;--awb-icon-width:22.1px;--awb-icon-height:22.1px;--awb-icon-margin:9.1px;--awb-content-margin:31.2px;" class="fusion-checklist fusion-checklist-1 fusion-checklist-default type-icons"><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa fa-play" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p><a href="http://prosurge.com/surge-protection-projects/" target="_blank" rel="noopener noreferrer">Prosurge&#8217;s Surge Protection Project Worldwide</a></p>
</div></li></ul><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-19 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element in-legacy-container" style="--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><span class=" fusion-imageframe imageframe-none imageframe-7 hover-type-none"><img decoding="async" width="600" height="333" alt="Lightning Stoke Density Map_600" title="Lightning Stoke Density Map_600" src="http://prosurge.com/wp-content/uploads/2019/03/Lightning-Stoke-Density-Map_600.jpg" class="img-responsive wp-image-15755" srcset="https://prosurge.com/wp-content/uploads/2019/03/Lightning-Stoke-Density-Map_600-200x111.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/Lightning-Stoke-Density-Map_600-400x222.jpg 400w, https://prosurge.com/wp-content/uploads/2019/03/Lightning-Stoke-Density-Map_600.jpg 600w" sizes="(max-width: 800px) 100vw, 600px" /></span></div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-7 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-20 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-15"><p><span style="color: #e02828;"><strong>2. Surge</strong></span></p>
<p>Well, we are going to talk more about surges in this session. Although we used the term surge many times in previous session, yet we haven&#8217;t given it a proper definition yet. And there are a lot of misunderstandings about this term.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-21 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-16"><p><strong>What is Surge?</strong></p>
<p>Here are some basic facts about surges.</p>
<ul>
<li>Surge, Transient, Spike: A sudden momentary rise in current or voltage in an electrical circuit.</li>
<li>It happen in millisecond (1/1000) or even microsecond (1/1000000).</li>
<li>Surge is not TOV (Temporary Overvoltage).</li>
<li>Surge is the most common cause of equipment damage and destruction. 31% of electronic equipment damage or losses are due to surges. (source from ABB)</li>
</ul>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-22 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element in-legacy-container" style="--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><span class=" fusion-imageframe imageframe-none imageframe-8 hover-type-none"><img decoding="async" width="400" height="273" alt="What is Surge_400" title="What is Surge_400" src="http://prosurge.com/wp-content/uploads/2019/03/What-is-Surge_400.jpg" class="img-responsive wp-image-15762" srcset="https://prosurge.com/wp-content/uploads/2019/03/What-is-Surge_400-200x137.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/What-is-Surge_400.jpg 400w" sizes="(max-width: 800px) 100vw, 400px" /></span></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-23 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-17"><p><strong>Surge VS Overvoltage</strong></p>
<p>Some people think that surge is overvoltage. Like the picture above shows, when the voltage spikes, there is a surge. Well, this is understandable yet not accurate, even very misleading. Surge is a kind of overvoltage yet overvoltage is not surge. We now know that surge happen in millisecond (1/1000) or even microsecond (1/1000000). However, overvoltage can last much longer, seconds, minutes even hours! There is a term called <b>temporary overvoltage (TOV)</b> to describe this long duration overvoltage.</p>
<p>In fact, not only surge and TOV are not the same thing, TOV is also the major killer for a surge protection device. An MOV based SPD can quickly lower its resistance to almost zero when a surge happens. Yet under continuous voltage, it burns quickly and thus poses a very serious safety threat. We&#8217;ll talk more about this in later session when we introduce surge protection devices.</p>
</div><div class="fusion-image-element in-legacy-container" style="--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><span class=" fusion-imageframe imageframe-none imageframe-9 hover-type-none"><img decoding="async" width="150" height="150" title="melt MOV" src="http://prosurge.com/wp-content/uploads/2018/03/melt-MOV-e1521524751571-150x150.png" alt class="img-responsive wp-image-13545" srcset="https://prosurge.com/wp-content/uploads/2018/03/melt-MOV-e1521524751571-66x66.png 66w, https://prosurge.com/wp-content/uploads/2018/03/melt-MOV-e1521524751571-150x150.png 150w, https://prosurge.com/wp-content/uploads/2018/03/melt-MOV-e1521524751571.png 367w" sizes="(max-width: 150px) 100vw, 150px" /></span></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-24 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-18"><div class="fusion-text">
<h3 style="text-align: left;" data-fontsize="17" data-lineheight="23"></h3>
</div>
<div class="fusion-text" style="text-align: left;">
<div class="table-1">
<table border="1" width="600" cellspacing="0" cellpadding="0" align="center">
<tbody>
<tr>
<td class="kso0" width="150"></td>
<td class="kso1" width="225">
<p style="text-align: center;" data-fontsize="17" data-lineheight="23"><strong>Temporary Overvoltage (TOV)</strong></p>
</td>
<td width="225">
<p style="text-align: center;" data-fontsize="17" data-lineheight="23"><strong> Surge</strong></p>
</td>
</tr>
<tr>
<td width="150">Caused by</td>
<td width="225">LV/HV-system faults</td>
<td width="225"> lightning or switching overvoltage</td>
</tr>
<tr>
<td width="150">Duration</td>
<td width="225">Long</p>
<p>millisecond to a few minutes</p>
<p>or hours</td>
<td width="225">Short</p>
<p>Microseconds (lightning)  or</p>
<p>millisecond (switching)</td>
</tr>
<tr>
<td width="150">MOV status</td>
<td width="225">Thermal runaway</td>
<td width="225">Self-recovery</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="fusion-sep-clear" style="text-align: left;"></div>
<div class="fusion-separator fusion-full-width-sep sep-none" style="text-align: left;"></div>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-25 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-26 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-19"><p><strong>What Causes Surge?</strong></p>
<p>These are some commonly acknowledged causes for surge:</p>
<ul>
<li>Lightning Stroke on a Lightning Rod</li>
<li>Lightning Stroke on a Aerial Line</li>
<li>Electromagnetic Induction</li>
<li>Switching Operation (much more frequent yet with lower energy)</li>
</ul>
<p>We can see that some are lightning related and some are not. Here is an illustration of lightning related surges.</p>
<p>Yet always keep in mind that not all surges are caused by lightning so its not only in thunderstorm that your equipments may get destructed.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-27 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-10 hover-type-none"><img decoding="async" width="758" height="364" alt="Lightning Related Surges" title="Lightning Related Surges_700" src="http://prosurge.com/wp-content/uploads/2019/03/Lightning-Related-Surges_700.jpg" class="img-responsive wp-image-15768" srcset="https://prosurge.com/wp-content/uploads/2019/03/Lightning-Related-Surges_700-200x96.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/Lightning-Related-Surges_700-400x192.jpg 400w, https://prosurge.com/wp-content/uploads/2019/03/Lightning-Related-Surges_700-600x288.jpg 600w, https://prosurge.com/wp-content/uploads/2019/03/Lightning-Related-Surges_700.jpg 758w" sizes="(max-width: 800px) 100vw, 600px" /></span></div></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-28 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-29 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-20"><p><strong>The Effects of Surge</strong></p>
<p>Surge can bring much harm and based on statistics, power surges cost US companies over $80 billion/year. Yet when we evaluate the effects of surge, we can&#8217;t limit ourselves on only seeing the visible. Actually, surge poses 4 different effects:</p>
<ul>
<li>Destruction</li>
<li>Degradation: Gradual deterioration of internal circuitry. Premature equipment failure. Normally caused by continuous low level surge, it doesn’t destroy the equipment at one time but overtime it destroy it.</li>
<li>Downtime: loss of productivity or important data</li>
<li>Safety Risk</li>
</ul>
<p>On the right is a video in which surge protection professionals do a test to verify how a surge protection device can truly prevent electrical products from surge destruction. You can see that when the DIN-rail SPD is removed, the coffee maker explodes when hit by surge generated by the lab.</p>
<p>This video presentation is really dramastic. However, some of surge&#8217;s damage is not so visible and dramastic yet it costs us dearly, for example, the downtime it brings. Image a company is experiencing downtime for a day, what would be the cost for that?</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-30 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-video fusion-youtube" style="--awb-max-width:600px;--awb-max-height:360px;"><div class="video-shortcode"><div class="fluid-width-video-wrapper" style="padding-top:60%;" ><iframe title="YouTube video player 3" src="https://www.youtube.com/embed/94-i2Hwt_Go?wmode=transparent&autoplay=0" width="600" height="360" allowfullscreen allow="autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture;"></iframe></div></div></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-31 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-21"><p>Surge not only brings property loss, but also brings personal safety risk.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-32 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-padding-left:200px;--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-11 hover-type-none"><img decoding="async" width="441" height="306" alt="Surge Cause Safety Risk High Speed Train_441" title="Surge Cause Safety Risk High Speed Train_441" src="http://prosurge.com/wp-content/uploads/2019/03/Surge-Cause-Safety-Risk-High-Speed-Train_441.jpg" class="img-responsive wp-image-15774" srcset="https://prosurge.com/wp-content/uploads/2019/03/Surge-Cause-Safety-Risk-High-Speed-Train_441-200x139.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/Surge-Cause-Safety-Risk-High-Speed-Train_441-400x278.jpg 400w, https://prosurge.com/wp-content/uploads/2019/03/Surge-Cause-Safety-Risk-High-Speed-Train_441.jpg 441w" sizes="(max-width: 800px) 100vw, 400px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-22"><p>The most catastrophic accident in China high speed train history is caused by lightning and surge. More than 200 casualties.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-33 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-padding-right:200px;--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-12 hover-type-none"><img decoding="async" width="420" height="306" alt="Surge Cause Safety Risk Oil Tank_420" title="Surge Cause Safety Risk Oil Tank_420" src="http://prosurge.com/wp-content/uploads/2019/03/Surge-Cause-Safety-Risk-Oil-Tank_420.jpg" class="img-responsive wp-image-15775" srcset="https://prosurge.com/wp-content/uploads/2019/03/Surge-Cause-Safety-Risk-Oil-Tank_420-200x146.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/Surge-Cause-Safety-Risk-Oil-Tank_420-400x291.jpg 400w, https://prosurge.com/wp-content/uploads/2019/03/Surge-Cause-Safety-Risk-Oil-Tank_420.jpg 420w" sizes="(max-width: 800px) 100vw, 400px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-23"><p>The Chinese lightning and surge industry began on 1989 after a catastrophic fire explosion accident on the oil storage tank due to lightning hit. And it also cause many casualties.</p>
</div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-8 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-34 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-24"><p><span style="color: #de1f1f;"><strong>3. Surge Protection Device / Surge Protective Device</strong></span></p>
<p>With the basic knowledge of lightning / surge protection and surge presented in previous session, we are going to learn more about surge protection device. Strangely, it should be called Surge Protective Device based all formal technical documents and standards. Yet many people, even professional in surge protection field like to use the term surge protection device. Maybe because it sounds more like a daily language.</p>
<p>Basically you can see two types of surge protection on the market like below pictures show. Note that pictures are not in acutal ratio of the item. Panel type SPD is normally much larger in size than DIN-rain SPD.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-35 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-padding-left:200px;--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-13 hover-type-none"><img decoding="async" width="200" height="200" alt="Panel Type Surge Protection Device" title="prosurge-surge-panel-PSP-C2-200" src="http://prosurge.com/wp-content/uploads/2018/09/prosurge-surge-panel-PSP-C2-200.jpg" class="img-responsive wp-image-14565" srcset="https://prosurge.com/wp-content/uploads/2018/09/prosurge-surge-panel-PSP-C2-200-66x66.jpg 66w, https://prosurge.com/wp-content/uploads/2018/09/prosurge-surge-panel-PSP-C2-200-150x150.jpg 150w, https://prosurge.com/wp-content/uploads/2018/09/prosurge-surge-panel-PSP-C2-200.jpg 200w" sizes="(max-width: 200px) 100vw, 200px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-25"><p style="text-align: center;">Panel Type Surge Protection Device</p>
<p style="text-align: center;">Popular in UL Standard Market</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-36 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-padding-right:200px;--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-14 hover-type-none"><img decoding="async" width="200" height="200" alt="DIN-rail Type Surge Protection Device" title="Prosurge AC DIN-rail SPD-200" src="http://prosurge.com/wp-content/uploads/2017/09/Prosurge-AC-DIN-rail-SPD-200.jpg" class="img-responsive wp-image-12424" srcset="https://prosurge.com/wp-content/uploads/2017/09/Prosurge-AC-DIN-rail-SPD-200-66x66.jpg 66w, https://prosurge.com/wp-content/uploads/2017/09/Prosurge-AC-DIN-rail-SPD-200-150x150.jpg 150w, https://prosurge.com/wp-content/uploads/2017/09/Prosurge-AC-DIN-rail-SPD-200.jpg 200w" sizes="(max-width: 200px) 100vw, 200px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-26"><p style="text-align: center;">DIN-rail Surge Protection Device</p>
<p style="text-align: center;">Popular in IEC Standard Market</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-37 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-27"><p>So What exactly is a surge protection device? As its name suggest, it is a device that protects against surges. But how? Does it eliminate the surge? Let&#8217;s take a look at the function of an surge protection device (SPD). We can say that an SPD is used to divert excess voltage and current safely to the ground before it reaches protected equipment. We can use surge protection equipments in lab to see its function.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-38 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-28"><p style="text-align: center;"><span style="color: #000080;"><strong>Without Surge Protection</strong></span></p>
</div><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-15 hover-type-none"><img decoding="async" width="612" height="200" alt="Without Surge Protection_600" title="Without Surge Protection_600" src="http://prosurge.com/wp-content/uploads/2019/03/Without-Surge-Protection_600.jpg" class="img-responsive wp-image-15783" srcset="https://prosurge.com/wp-content/uploads/2019/03/Without-Surge-Protection_600-200x65.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/Without-Surge-Protection_600-400x131.jpg 400w, https://prosurge.com/wp-content/uploads/2019/03/Without-Surge-Protection_600-600x196.jpg 600w, https://prosurge.com/wp-content/uploads/2019/03/Without-Surge-Protection_600.jpg 612w" sizes="(max-width: 800px) 100vw, 600px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-29"><p style="text-align: center;">Voltage up to 4967V and will damage the protected equipment</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-39 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-30"><p style="text-align: center;"><span style="color: #000080;"><strong>With Surge Protection</strong></span></p>
</div><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-16 hover-type-none"><img decoding="async" width="500" height="197" alt="With Surge Protection_500" title="With Surge Protection_500" src="http://prosurge.com/wp-content/uploads/2019/03/With-Surge-Protection_500.jpg" class="img-responsive wp-image-15784" srcset="https://prosurge.com/wp-content/uploads/2019/03/With-Surge-Protection_500-200x79.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/With-Surge-Protection_500-400x158.jpg 400w, https://prosurge.com/wp-content/uploads/2019/03/With-Surge-Protection_500.jpg 500w" sizes="(max-width: 800px) 100vw, 500px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-31"><p style="text-align: center;">Voltage is limited to 352V</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-40 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-32"><p><strong>How does SPD work?</strong></p>
<p>SPD is voltage sensitive. Its resistance reduced sharply as voltage increase. You can imagine SPD as a gate and surge as flood. Under normal situation, the gate is shut but when seeing surge voltage coming, the gate quickly open so the surge can be diverted away. It will automatically reset to high impedance status after the surge ends.</p>
<p>SPD takes the surge so the protected equipment can survive. Overtime, SPD will come to end of life due to the many surges it endures. It sacrifices itself so the protected equipment can live.</p>
<p>The ultimate fate for an SPD is to sacrifice.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-41 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-padding-left:150px;--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element in-legacy-container" style="--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><span class=" fusion-imageframe imageframe-none imageframe-17 hover-type-none"><img decoding="async" width="500" height="381" alt="How Does SPD Work_500" title="How Does SPD Work_500" src="http://prosurge.com/wp-content/uploads/2019/03/How-Does-SPD-Work_500.jpg" class="img-responsive wp-image-15788" srcset="https://prosurge.com/wp-content/uploads/2019/03/How-Does-SPD-Work_500-200x152.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/How-Does-SPD-Work_500-400x305.jpg 400w, https://prosurge.com/wp-content/uploads/2019/03/How-Does-SPD-Work_500.jpg 500w" sizes="(max-width: 800px) 100vw, 400px" /></span></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-42 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element in-legacy-container" style="--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><span class=" fusion-imageframe imageframe-none imageframe-18 hover-type-none"><img decoding="async" width="470" height="381" alt="How Does SPD Work-2" title="How Does SPD Work-2" src="http://prosurge.com/wp-content/uploads/2019/03/How-Does-SPD-Work-2.jpg" class="img-responsive wp-image-15789" srcset="https://prosurge.com/wp-content/uploads/2019/03/How-Does-SPD-Work-2-200x162.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/How-Does-SPD-Work-2-400x324.jpg 400w, https://prosurge.com/wp-content/uploads/2019/03/How-Does-SPD-Work-2.jpg 470w" sizes="(max-width: 800px) 100vw, 470px" /></span></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-43 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-33"><p><strong>Surge Protection Components</strong></p>
<p>In this session, we are going to talk about SPD components. Basically, there are 4 major SPD components: spark gap, MOV, GDT and TVS. These components have different characteristics yet they all serve a similar function: understand normal situation, their resistance is so huge that no current can follow yet under surge situation their resistance instantly drop to almost zero so that the surge current can pass to the ground instead of flowing to the protected downstream equipments. That&#8217;s why we call these 4 components non-linear components. Yet they do have differences and we may write another article to talk about their differences. But for now, all we need to know is that they all serve the same function: to divert to the surge current to the ground.</p>
<p>Let&#8217;s take a look at these surge protection components.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-44 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-first" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% + 4% ) * 0.33333333333333 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-19 hover-type-none"><img decoding="async" width="234" height="234" alt="SPD Component-MOV 34D" title="SPD Component-MOV 34D" src="http://prosurge.com/wp-content/uploads/2019/03/SPD-Component-MOV-34D.jpg" class="img-responsive wp-image-15794" srcset="https://prosurge.com/wp-content/uploads/2019/03/SPD-Component-MOV-34D-200x200.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/SPD-Component-MOV-34D.jpg 234w" sizes="(max-width: 800px) 100vw, 234px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-34"><p style="text-align: center;">Metal Oxide Varistor (MOV)</p>
<p style="text-align: center;">The Most Common SPD Component</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-45 fusion_builder_column_1_3 1_3 fusion-one-third" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% + 4% ) * 0.33333333333333 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-20 hover-type-none"><img decoding="async" width="312" height="217" alt="Surge Protection Components - Gas Discharge Tube GDT_217" title="Surge Protection Components &#8211; Gas Discharge Tube GDT_217" src="http://prosurge.com/wp-content/uploads/2019/03/Surge-Protection-Components-Gas-Discharge-Tube-GDT_217.jpg" class="img-responsive wp-image-15796" srcset="https://prosurge.com/wp-content/uploads/2019/03/Surge-Protection-Components-Gas-Discharge-Tube-GDT_217-200x139.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/Surge-Protection-Components-Gas-Discharge-Tube-GDT_217.jpg 312w" sizes="(max-width: 800px) 100vw, 312px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-35"><p style="text-align: center;">Gas Discharge Tube (GDT)</p>
<p style="text-align: center;">Can Used in Hybrid with MOV</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-46 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-last" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% + 4% ) * 0.33333333333333 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-21 hover-type-none"><img decoding="async" width="396" height="217" alt="Surge Protection Components - Transient Surge Suppressor TVS_217" title="Surge Protection Components &#8211; Transient Surge Suppressor TVS_217" src="http://prosurge.com/wp-content/uploads/2019/03/Surge-Protection-Components-Transient-Surge-Suppressor-TVS_217.jpg" class="img-responsive wp-image-15797" srcset="https://prosurge.com/wp-content/uploads/2019/03/Surge-Protection-Components-Transient-Surge-Suppressor-TVS_217-200x110.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/Surge-Protection-Components-Transient-Surge-Suppressor-TVS_217.jpg 396w" sizes="(max-width: 800px) 100vw, 396px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-36"><p style="text-align: center;">Transient Surge Suppressor (TVS)</p>
<p style="text-align: center;">Popular in Data/Signal SPD Due to Its Tiny Size</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-47 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-37"><p><strong>Metal Oxide Varistor (MOV) and Its Evolution</strong></p>
<p>MOV is the most common SPD component and thus we&#8217;ll talk more about it. The first thing to remember is that MOV is not a perfect component.</p>
<p>Comprised typically of zinc oxide that conducts when it is exposed to an overvoltage that exceeds its rating, MOVs have a finite life expectancy and degraded when exposed to a few large surges or many smaller surges, and will eventually short to ground creating an end of life scenario. This condition will cause a circuit breaker to trip or a fused link to open. Large transients may cause the component to open and thus bring about a more violent end to the component itself. MOV is typically used to suppress surge found in AC power circuits.</p>
<p>In this ABB video, they give a very clear illustration of how MOV works.</p>
<p>SPD manufacturers do a lot a research on the safety of SPD and a lot of such work is to solve the safety problem of MOV. MOV has been evolved during the past 2 decades. Now we have updated MOV like TMOV (normally a MOV with built-in fuse) or TPMOV (thermally protected MOV) which improve its safety. Prosurge, as one of the leading TPMOV manufacturer, has contributed our efforts to the better performance of MOV.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-48 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-video fusion-youtube" style="--awb-max-width:600px;--awb-max-height:360px;"><div class="video-shortcode"><div class="fluid-width-video-wrapper" style="padding-top:60%;" ><iframe title="YouTube video player 4" src="https://www.youtube.com/embed/tfXoOfipO08?wmode=transparent&autoplay=0" width="600" height="360" allowfullscreen allow="autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture;"></iframe></div></div></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-49 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-38"><p>Prosurge&#8217;s SMTMOV and PTMOV are two updated version of traditional MOV. They are fail-safe and self-protected components adopted by major SPD manufactures to build their surge protection products.</p>
</div><ul style="--awb-size:13px;--awb-iconcolor:#f44336;--awb-line-height:22.1px;--awb-icon-width:22.1px;--awb-icon-height:22.1px;--awb-icon-margin:9.1px;--awb-content-margin:31.2px;" class="fusion-checklist fusion-checklist-2 fusion-checklist-default type-icons"><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa fa-play" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p><a href="http://prosurge.com/tpmov-thermally-protected-mov/" target="_blank" rel="noopener noreferrer">Check Prosurge&#8217;s Thermally Protected MOV</a></p>
</div></li></ul><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-50 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-padding-left:250px;--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-22 hover-type-none"><img decoding="async" width="274" height="300" alt="PTMOV150_274×300_Prosurge Thermally Protected MOV" title="PTMOV150_274×300_Prosurge-Thermally-Protected-MOV" src="http://prosurge.com/wp-content/uploads/2019/03/PTMOV150_274×300_Prosurge-Thermally-Protected-MOV.jpg" class="img-responsive wp-image-15886" srcset="https://prosurge.com/wp-content/uploads/2019/03/PTMOV150_274×300_Prosurge-Thermally-Protected-MOV-200x219.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/PTMOV150_274×300_Prosurge-Thermally-Protected-MOV.jpg 274w" sizes="(max-width: 800px) 100vw, 200px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-39"><p style="text-align: center;">25kA TPMOV</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-51 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-padding-right:250px;--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-23 hover-type-none"><img decoding="async" width="212" height="300" alt="SMTMOV150_212×300_Prosurge-Thermally-Protected-MOV" title="SMTMOV150_212×300_Prosurge-Thermally-Protected-MOV" src="http://prosurge.com/wp-content/uploads/2019/03/SMTMOV150_212×300_Prosurge-Thermally-Protected-MOV.jpg" class="img-responsive wp-image-15887" srcset="https://prosurge.com/wp-content/uploads/2019/03/SMTMOV150_212×300_Prosurge-Thermally-Protected-MOV-200x283.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/SMTMOV150_212×300_Prosurge-Thermally-Protected-MOV.jpg 212w" sizes="(max-width: 800px) 100vw, 200px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-40"><p style="text-align: center;">50kA/75kA TPMOV</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-52 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-41"><p><strong>Surge Protection Device Standards</strong></p>
<p>Generally speaking, there are two major standards: IEC standard and UL standard. UL standard is mainly applicable in North America and some parts in South America and Philippines. Clearly IEC standard is more extensively applicable around the world. Even the Chinese standard GB 18802 is borrowed from IEC 61643-11 standard.</p>
<p>Why can&#8217;t we have a universal standard around the world? Well, one of the explanation is that European experts and US experts have different opinions on the understanding of lightning and surge.</p>
<p>Surge protection is still an evolving subject. For example, previous there is no official IEC standard in SPD used in DC/PV application. The prevailing IEC 61643-11 is only for AC power supply. Yet now we have the newly released IEC 61643-31 standard for SPD used in DC/PV application.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-53 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-padding-left:250px;--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-42"><p style="text-align: center;"><strong>IEC Market</strong></p>
<p style="text-align: center;">IEC 61643-11 (AC Power System)</p>
<p style="text-align: center;">IEC 61643-32 (DC Power System)</p>
<p style="text-align: center;">IEC 61643-21 (Data &amp; Signal)</p>
<p style="text-align: center;">EN 50539-11 = IEC 61643-32</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-54 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-padding-right:250px;--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-43"><p style="text-align: center;"><strong>UL Market</strong></p>
<p style="text-align: center;">UL 1449 4th Edition (Both AC and DC Power System)</p>
<p style="text-align: center;">UL 497B (Data &amp; Signal)</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-55 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-44"><p><strong>Surge Protection Device Installation</strong></p>
<p>Well, this may be the most easy session to write about because our suggestion is that you can go to Youtube because there are a lot of videos about SPD installation, either be a DIN-rail SPD or a panel SPD. Of course, you can check our project photos to learn more about. Noted that the installation of an surge protection device should be done by a qualified / licensed electrician.</p>
</div><ul style="--awb-size:13px;--awb-iconcolor:#f44336;--awb-line-height:22.1px;--awb-icon-width:22.1px;--awb-icon-height:22.1px;--awb-icon-margin:9.1px;--awb-content-margin:31.2px;" class="fusion-checklist fusion-checklist-3 fusion-checklist-default type-icons"><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa fa-play" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p><a href="http://prosurge.com/surge-protection-projects/" target="_blank" rel="noopener noreferrer">Prosurge&#8217;s Surge Protection Project</a></p>
</div></li></ul><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-56 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-45"><p><strong>Surge Protection Device Classifications</strong></p>
<p>There are several ways to classify surge protection device.</p>
<ul>
<li>By Installation: DIN-rail SPD VS Panel SPD</li>
<li>By Standard: IEC Standard VS UL Standard</li>
<li>By AC/DC: AC Power SPD VS DC Power SPD</li>
<li>By Location: Type 1/2/3 SPD</li>
</ul>
<p>We&#8217;ll introduce in details the classification of UL 1449 standard. Basically, in UL standard the type of an SPD is determined by its installation location. If you would like to learn more, we suggest you to read this article published by NEMA.</p>
</div><ul style="--awb-size:13px;--awb-iconcolor:#f44336;--awb-line-height:22.1px;--awb-icon-width:22.1px;--awb-icon-height:22.1px;--awb-icon-margin:9.1px;--awb-content-margin:31.2px;" class="fusion-checklist fusion-checklist-4 fusion-checklist-default type-icons"><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa fa-play" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p><a href="https://www.nemasurge.org/wp-content/uploads/2011/09/SPD-Type-Application-Considerations-Rev-Date-01-31-2013.pdf" target="_blank" rel="noopener noreferrer">Surge Protection Device Classification</a></p>
</div></li></ul><div class="fusion-text fusion-text-46"><p>Also we find a Video on Youtube presented by Jeff Cox that gives a very clear introduction of the different types on surge protection device.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-57 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-video fusion-youtube" style="--awb-max-width:600px;--awb-max-height:360px;"><div class="video-shortcode"><div class="fluid-width-video-wrapper" style="padding-top:60%;" ><iframe title="YouTube video player 5" src="https://www.youtube.com/embed/VTzZednACWE?wmode=transparent&autoplay=0" width="600" height="360" allowfullscreen allow="autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture;"></iframe></div></div></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-58 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-47"><p>Here are some pictures of type 1/2/3 surge protection device in UL standard.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-59 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-first" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% + 4% ) * 0.33333333333333 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-24 hover-type-none"><img decoding="async" width="250" height="250" alt="Type 1 surge protection device" title="prosurge-surge-panel-PSP-C2-250" src="http://prosurge.com/wp-content/uploads/2018/09/prosurge-surge-panel-PSP-C2-250.jpg" class="img-responsive wp-image-14633" srcset="https://prosurge.com/wp-content/uploads/2018/09/prosurge-surge-panel-PSP-C2-250-200x200.jpg 200w, https://prosurge.com/wp-content/uploads/2018/09/prosurge-surge-panel-PSP-C2-250.jpg 250w" sizes="(max-width: 800px) 100vw, 250px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-48"><p style="text-align: center;">Type 1 Surge Protection Device: First Line of Defence</p>
<p style="text-align: center;">Installed outside the building at service entrance</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-60 fusion_builder_column_1_3 1_3 fusion-one-third" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% + 4% ) * 0.33333333333333 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-25 hover-type-none"><img decoding="async" width="250" height="250" alt="Type 2 surge protection device" title="prosurge-surge-panel-PSP-C1-250" src="http://prosurge.com/wp-content/uploads/2018/09/prosurge-surge-panel-PSP-C1-250.jpg" class="img-responsive wp-image-14632" srcset="https://prosurge.com/wp-content/uploads/2018/09/prosurge-surge-panel-PSP-C1-250-200x200.jpg 200w, https://prosurge.com/wp-content/uploads/2018/09/prosurge-surge-panel-PSP-C1-250.jpg 250w" sizes="(max-width: 800px) 100vw, 250px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-49"><p style="text-align: center;">Type 2 Surge Protection Device: Second Line of Defence</p>
<p style="text-align: center;">Installed inside the building at branch panel</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-61 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-last" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% + 4% ) * 0.33333333333333 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-26 hover-type-none"><img decoding="async" width="470" height="250" alt="Type 3 Surge Protection Device_250" title="Type 3 Surge Protection Device_250" src="http://prosurge.com/wp-content/uploads/2019/03/Type-3-Surge-Protection-Device_250.jpg" class="img-responsive wp-image-15809" srcset="https://prosurge.com/wp-content/uploads/2019/03/Type-3-Surge-Protection-Device_250-200x106.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/Type-3-Surge-Protection-Device_250-400x213.jpg 400w, https://prosurge.com/wp-content/uploads/2019/03/Type-3-Surge-Protection-Device_250.jpg 470w" sizes="(max-width: 800px) 100vw, 400px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:20px;margin-bottom:20px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-50"><p style="text-align: center;">Type 3 Surge Protection Device: Last Line of Defence</p>
<p style="text-align: center;">Normally refer to Surge Strip and Receptacle installed next to the protected equipment</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-62 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-51"><p>Noted that IEC 61643-11 standard also adopts similar terms like type 1/2/3 SPD or Class I/II/III SPD. These terms, though differs from the terms in UL standard, share similar principle. Class I SPD takes the initial surge energy which is the strongest and Class II and Class III SPDs handle the remaining surge energy which is already diminished. Together, the Class I/II/III surge protection devices forms an coordinated multi-layered surge protection systems which is considered to be the most effective.</p>
<p>The picture on the right shows the SPD at every level on installation in IEC standard.</p>
<p>We&#8217;ll talk a little bit about one difference between the type 1/2/3 in UL standard and IEC standard. In IEC standard, there is a term called lightning impulse current and its sign is Iimp. It is a simulation of the impulse of direct lightning and its energy is in the waveform of 10/350. Type 1 SPD in IEC standard must indicate its Iimp and SPD manufacturers normally use spark gap technology for type 1 SPD as spark gap technology allows a higher Iimp than MOV technology in the same size. Yet the term Iimp is not recognized by UL standard.</p>
<p>Also another key difference is that SPD in IEC standard are normally DIN-rail mounted yet SPD in UL standard are hard-wired or panel mounted. They look different. Here is some pictures of IEC standard SPD.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-63 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element in-legacy-container" style="--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><span class=" fusion-imageframe imageframe-none imageframe-27 hover-type-none"><img decoding="async" width="600" height="309" alt="Surge Protection Device Types _ IEC 61643-11_600" title="Surge Protection Device Types _ IEC 61643-11_600" src="http://prosurge.com/wp-content/uploads/2019/03/Surge-Protection-Device-Types-_-IEC-61643-11_600.jpg" class="img-responsive wp-image-15816" srcset="https://prosurge.com/wp-content/uploads/2019/03/Surge-Protection-Device-Types-_-IEC-61643-11_600-200x103.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/Surge-Protection-Device-Types-_-IEC-61643-11_600-400x206.jpg 400w, https://prosurge.com/wp-content/uploads/2019/03/Surge-Protection-Device-Types-_-IEC-61643-11_600.jpg 600w" sizes="(max-width: 800px) 100vw, 600px" /></span></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-64 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-first" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% + 4% ) * 0.33333333333333 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-28 hover-type-none"><img decoding="async" width="374" height="300" alt="Type 1 Surge Protection Device SPD-400" title="Type 1 Surge Protection Device SPD-300" src="http://prosurge.com/wp-content/uploads/2019/03/Type-1-Surge-Protection-Device-SPD-300.jpg" class="img-responsive wp-image-15819" srcset="https://prosurge.com/wp-content/uploads/2019/03/Type-1-Surge-Protection-Device-SPD-300-200x160.jpg 200w, https://prosurge.com/wp-content/uploads/2019/03/Type-1-Surge-Protection-Device-SPD-300.jpg 374w" sizes="(max-width: 800px) 100vw, 374px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-52"><p style="text-align: center;">Type 1/Class I SPD</p>
<p style="text-align: center;">First Line of Defense</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-65 fusion_builder_column_1_3 1_3 fusion-one-third" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% + 4% ) * 0.33333333333333 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-29 hover-type-none"><img decoding="async" width="278" height="300" alt="Type 2 Surge Protection Device SPD" title="Prosurge-AC-DIN-rail-SPD-KEMA-300" src="http://prosurge.com/wp-content/uploads/2018/09/Prosurge-AC-DIN-rail-SPD-KEMA-300-278x300.jpg" class="img-responsive wp-image-14625" srcset="https://prosurge.com/wp-content/uploads/2018/09/Prosurge-AC-DIN-rail-SPD-KEMA-300-200x216.jpg 200w, https://prosurge.com/wp-content/uploads/2018/09/Prosurge-AC-DIN-rail-SPD-KEMA-300.jpg 303w" sizes="(max-width: 800px) 100vw, 278px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-53"><p style="text-align: center;">Type 2/Class II SPD</p>
<p style="text-align: center;">Second Line of Defense</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-66 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-last" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% + 4% ) * 0.33333333333333 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-30 hover-type-none"><img decoding="async" width="186" height="320" alt="Type 3 Surge Protection Device SPD" title="Class-III-Type-3-SPD-Prosurge-186×320" src="http://prosurge.com/wp-content/uploads/2019/03/Class-III-Type-3-SPD-Prosurge-186×320-1.jpg" class="img-responsive wp-image-15888" srcset="https://prosurge.com/wp-content/uploads/2019/03/Class-III-Type-3-SPD-Prosurge-186×320-1-174x300.jpg 174w, https://prosurge.com/wp-content/uploads/2019/03/Class-III-Type-3-SPD-Prosurge-186×320-1.jpg 186w" sizes="(max-width: 186px) 100vw, 186px" /></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:10px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-54"><p style="text-align: center;">Type 3/Class III SPD</p>
<p style="text-align: center;">Last Line of Defense</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-67 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-55"><p>As for other classifications, we may elaborate them later in other articles as it may be quite lengthy. Right now, all you need to know is that SPD is classified by types both in UL and IEC standards.</p>
</div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:15px;margin-bottom:15px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-68 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-56"><p><strong>Key Parameters of Surge Protection Device</strong></p>
<p>If you look at a surge protection device, you&#8217;ll see several parameters on its marking, for example, MCOV, In, Imax, VPR, SCCR. What do they mean and why it is important? Well, in this session, we are going to talk about it.</p>
<p><span style="color: #000080;"><strong>Nominal Voltage (Un) </strong></span></p>
<p>Nominal means &#8216;named&#8217;. So a nominal voltage is the &#8216;named&#8217; voltage. For example, the nominal voltage of the supply system in many countries is 220 V. But its actual value is allowed to vary between a narrow range.</p>
<p><span style="color: #000080;"><strong>Maximum Continuous Operating Voltage (MCOV/Uc) </strong></span></p>
<p>The highest amount of voltage the device will allow to pass through continuously. MCOV is normally 1.1-1.2 time higher than Un. But in area with unstable power grid, voltage will go very high and thus must select a higher MCOV SPD. For 220V Un, European countries can choose 250V MCOV SPD but in some markets like India, we recommend MCOV 320V or even 385V. Notice: Voltage above MCOV is called Temporary Overvoltage (TOV). More than 90% of SPD burnt is due to TOV.</p>
<p><span style="color: #333399;"><strong>Voltage Protection Rating (VPR) / Let-through Voltage</strong></span></p>
<p>It is the maximum amount of voltage that a SPD will allow to pass through to the protected device and of course it is the lower the better. For example, the protected device can withstand maximum 800V. If the SPD’s VRP is 1000V, the protected device will be damaged or degraded.</p>
<p><span style="color: #000080;"><strong>Surge Current Capacity</strong></span></p>
<p>It is the maximum amount of surge current a SPD can shunt to ground during a surge event and is an indicator of life span of a SPD. For example, a 200kA SPD has a longer life span than a 100kA SPD under same situation.</p>
<p><span style="color: #333399;"><strong>Nominal Discharge Current (In) </strong></span></p>
<p>It is the peak value of the surge current through the SPD. SPD need to remain functional after 15 In surges. It is indicator of the robustness of a SPD and it is measure of how the SPD performs when installed and subjected to operating scenarios closer to real life situation The higher the better.</p>
<p><span style="color: #000080;"><strong>Maximum Discharge Current (Imax)</strong></span></p>
<p>It is the peak value of the surge current through the SPD. SPD need to remain functional after 1 Imax surges. Typically, it is 2-2.5 time of the value of In. It is also the indicator of the robustness of a SPD. But it is an less important parameter than In because Imax is an extreme test and in real situation, surge normally will not have such strong energy. For this parameter, the higher the better.</p>
<p><span style="color: #333399;"><strong>Short Circuit Current Rating (SCCR)</strong></span></p>
<p>It is the maximum level of short-circuit current that a component or assembly can withstand and the higher the better. Prosurge’s major SPDs passed 200kA SCCR test per UL standard without external circuit breaker and fuse which is the best performance in industry.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-69 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-57"><p><strong>Surge Protection Device Applications</strong></p>
<p>Surge protection devices are applied extensively on various industries, especially for those critical-mission industries. Below is a list of surge protection applications and solutions that Prosurge prepare. In each applications, we indicates the SPD required and its installation locations. If you are interested in any of the applications, you can click and learn more.</p>
</div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-9 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-right:0px;--awb-padding-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-70 fusion_builder_column_1_4 1_4 fusion-one-fourth fusion-column-first" style="--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% + 4% ) * 0.25 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-31 hover-type-zoomin"><a class="fusion-no-lightbox" href="http://prosurge.com/surge-protection-for-building/" target="_self" aria-label="Surge Protection Solution for Building &#8211; Prosurge"><img decoding="async" width="300" height="200" src="http://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Building-Prosurge-1.jpg" alt class="img-responsive wp-image-11986" srcset="https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Building-Prosurge-1-200x133.jpg 200w, https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Building-Prosurge-1.jpg 300w" sizes="(max-width: 800px) 100vw, 200px" /></a></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:20px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-58"><p style="text-align: center;"><strong>Building</strong></p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-71 fusion_builder_column_1_4 1_4 fusion-one-fourth" style="--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% + 4% ) * 0.25 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-32 hover-type-zoomin"><a class="fusion-no-lightbox" href="http://prosurge.com/surge-protection-for-solar-power-or-pv-system/" target="_self" aria-label="Surge Protection Solution for solar power or PV sysem- Prosurge"><img decoding="async" width="300" height="200" src="http://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-solar-power-or-PV-sysem-Prosurge.jpg" alt class="img-responsive wp-image-11993" srcset="https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-solar-power-or-PV-sysem-Prosurge-200x133.jpg 200w, https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-solar-power-or-PV-sysem-Prosurge.jpg 300w" sizes="(max-width: 800px) 100vw, 200px" /></a></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:20px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-59"><p style="text-align: center;"><b>Solar Power / PV System</b></p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-72 fusion_builder_column_1_4 1_4 fusion-one-fourth" style="--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% + 4% ) * 0.25 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-33 hover-type-zoomin"><a class="fusion-no-lightbox" href="http://prosurge.com/surge-protection-for-led-street-lighting/" target="_self" aria-label="Surge Protection Solution for LED Street Lighting &#8211; Prosurge"><img decoding="async" width="300" height="200" src="http://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-LED-Street-Lighting-Prosurge.jpg" alt class="img-responsive wp-image-12270" srcset="https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-LED-Street-Lighting-Prosurge-200x133.jpg 200w, https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-LED-Street-Lighting-Prosurge.jpg 300w" sizes="(max-width: 800px) 100vw, 200px" /></a></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:20px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-60"><p style="text-align: center;"><strong>LED Street Light</strong></p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-73 fusion_builder_column_1_4 1_4 fusion-one-fourth fusion-column-last" style="--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% + 4% ) * 0.25 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-34 hover-type-zoomin"><a class="fusion-no-lightbox" href="http://prosurge.com/surge-protection-for-oil-gas-station/" target="_self" aria-label="Surge Protection Solution for oil station- Prosurge"><img decoding="async" width="300" height="200" src="http://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-oil-station-Prosurge.jpg" alt class="img-responsive wp-image-11988" srcset="https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-oil-station-Prosurge-200x133.jpg 200w, https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-oil-station-Prosurge.jpg 300w" sizes="(max-width: 800px) 100vw, 200px" /></a></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:20px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-61"><p style="text-align: center;"><strong>Oil &amp; Gas Station</strong></p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-74 fusion_builder_column_1_4 1_4 fusion-one-fourth fusion-column-first" style="--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% + 4% ) * 0.25 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-35 hover-type-zoomin"><a class="fusion-no-lightbox" href="http://prosurge.com/surge-protection-for-telecom/" target="_self" aria-label="Surge Protection Solution for Telecom &#8211; Prosurge"><img decoding="async" width="300" height="200" src="http://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Telecom-Prosurge.jpg" alt class="img-responsive wp-image-11989" srcset="https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Telecom-Prosurge-200x133.jpg 200w, https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Telecom-Prosurge.jpg 300w" sizes="(max-width: 800px) 100vw, 200px" /></a></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:20px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-62"><p style="text-align: center;"><strong>Telecom</strong></p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-75 fusion_builder_column_1_4 1_4 fusion-one-fourth" style="--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% + 4% ) * 0.25 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-36 hover-type-zoomin"><a class="fusion-no-lightbox" href="http://prosurge.com/surge-protection-for-led-display/" target="_self" aria-label="Surge Protection Solution for LED Display &#8211; Prosurge"><img decoding="async" width="300" height="200" src="http://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-LED-Display-Prosurge.jpg" alt class="img-responsive wp-image-11990" srcset="https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-LED-Display-Prosurge-200x133.jpg 200w, https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-LED-Display-Prosurge.jpg 300w" sizes="(max-width: 800px) 100vw, 200px" /></a></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:20px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-63"><p style="text-align: center;"><strong>LED Display</strong></p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-76 fusion_builder_column_1_4 1_4 fusion-one-fourth" style="--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% + 4% ) * 0.25 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-37 hover-type-zoomin"><a class="fusion-no-lightbox" href="http://prosurge.com/surge-protection-for-industrial-control-system/" target="_self" aria-label="Surge Protection Solution for Industrial control system- Prosurge"><img decoding="async" width="300" height="200" src="http://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Industrial-control-system-Prosurge.jpg" alt class="img-responsive wp-image-11992" srcset="https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Industrial-control-system-Prosurge-200x133.jpg 200w, https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Industrial-control-system-Prosurge.jpg 300w" sizes="(max-width: 800px) 100vw, 200px" /></a></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:20px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-64"><p style="text-align: center;"><strong>Industrial Control</strong></p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-77 fusion_builder_column_1_4 1_4 fusion-one-fourth fusion-column-last" style="--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% + 4% ) * 0.25 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-38 hover-type-zoomin"><a class="fusion-no-lightbox" href="http://prosurge.com/surge-protection-for-cctv-system/" target="_self" aria-label="Surge Protection Solution for CCTV &#8211; Prosurge"><img decoding="async" width="300" height="200" src="http://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-CCTV-Prosurge.jpg" alt class="img-responsive wp-image-11983" srcset="https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-CCTV-Prosurge-200x133.jpg 200w, https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-CCTV-Prosurge.jpg 300w" sizes="(max-width: 800px) 100vw, 200px" /></a></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:20px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-65"><p style="text-align: center;"><strong>CCTV System</strong></p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-78 fusion_builder_column_1_4 1_4 fusion-one-fourth fusion-column-first" style="--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% ) * 0.25 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-39 hover-type-zoomin"><a class="fusion-no-lightbox" href="http://prosurge.com/surge-protection-for-electric-vehicle-charging-station/" target="_self" aria-label="Surge Protection Solution for Vehicle charging system- Prosurge"><img decoding="async" width="300" height="200" src="http://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Vehicle-charging-system-Prosurge.jpg" alt class="img-responsive wp-image-11994" srcset="https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Vehicle-charging-system-Prosurge-200x133.jpg 200w, https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Vehicle-charging-system-Prosurge.jpg 300w" sizes="(max-width: 800px) 100vw, 200px" /></a></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:20px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-66"><p style="text-align: center;"><strong>Vehicle Charging System</strong></p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-79 fusion_builder_column_1_4 1_4 fusion-one-fourth" style="--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% ) * 0.25 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-40 hover-type-zoomin"><a class="fusion-no-lightbox" href="http://prosurge.com/surge-protection-for-wind-turbine/" target="_self" aria-label="Surge protection for Wind Turbine-prosurge"><img decoding="async" width="300" height="200" src="http://prosurge.com/wp-content/uploads/2017/10/Surge-protection-for-Wind-Turbine-prosurge.jpg" alt class="img-responsive wp-image-12050" srcset="https://prosurge.com/wp-content/uploads/2017/10/Surge-protection-for-Wind-Turbine-prosurge-200x133.jpg 200w, https://prosurge.com/wp-content/uploads/2017/10/Surge-protection-for-Wind-Turbine-prosurge.jpg 300w" sizes="(max-width: 800px) 100vw, 200px" /></a></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:20px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-67"><p style="text-align: center;"><strong>Wind Turbine</strong></p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-80 fusion_builder_column_1_4 1_4 fusion-one-fourth fusion-column-last" style="--awb-bg-size:cover;width:25%;width:calc(25% - ( ( 4% + 4% ) * 0.25 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-41 hover-type-zoomin"><a class="fusion-no-lightbox" href="http://prosurge.com/surge-protection-for-railway-system/" target="_self" aria-label="Surge Protection Solution for Railway System &#8211; Prosurge"><img decoding="async" width="300" height="200" src="http://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Railway-System-Prosurge.jpg" alt class="img-responsive wp-image-11984" srcset="https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Railway-System-Prosurge-200x133.jpg 200w, https://prosurge.com/wp-content/uploads/2017/10/Surge-Protection-Solution-for-Railway-System-Prosurge.jpg 300w" sizes="(max-width: 800px) 100vw, 200px" /></a></span></div></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:20px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-68"><p style="text-align: center;"><strong>Railway System</strong></p>
</div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-10 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-81 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:15px;margin-bottom:15px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-69"><p><span style="color: #e02828;"><strong>Summary</strong></span></p>
<p>Finally, we come to the end of this article. In this article, we talk about some interesting stuff like lightning protection, surge protection, surge and surge protection device. I hope that you already understand the basics of surge protection device. But if you would like to learn more about this subject, we have other articles on our surge protection education section on our website.</p>
</div><ul style="--awb-size:13px;--awb-iconcolor:#f44336;--awb-line-height:22.1px;--awb-icon-width:22.1px;--awb-icon-height:22.1px;--awb-icon-margin:9.1px;--awb-content-margin:31.2px;" class="fusion-checklist fusion-checklist-5 fusion-checklist-default type-icons"><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa fa-play" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p><a href="http://prosurge.com/surge-protection-education/">Surge Protection Education</a></p>
</div></li></ul><div class="fusion-text fusion-text-70"><p>And the last yet most important part of this article is to offer our thanks to those companies who produce a lot of videos, photos, articles and all kinds of material on the subject of surge protection. They are the forerunner in our industry. Inspired by them, we are contributing our share too.</p>
<p>If you like this article, you can help share it!</p>
</div><div class="fusion-clearfix"></div></div></div></div></div></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to choose a surge protection device (SPD)?</title>
		<link>https://prosurge.com/how-to-choose-a-surge-protection-device-spd/</link>
		
		<dc:creator><![CDATA[prosurge]]></dc:creator>
		<pubDate>Fri, 15 Feb 2019 10:08:55 +0000</pubDate>
				<category><![CDATA[Surge Protection Education]]></category>
		<category><![CDATA[SPD]]></category>
		<category><![CDATA[surge protection device]]></category>
		<guid isPermaLink="false">http://prosurge.com/?p=15583</guid>

					<description><![CDATA[Surge Protective Devices (SPD) are used to protect electrical equipment against surges (overvoltages) caused by lightning or switch of heavy duty machines (many people may ignore this). It may take some technical background when selecting a proper surge protective device as there are various technologies and regulations. The IEC 61643 standard defines 3 types  [...]]]></description>
										<content:encoded><![CDATA[<p><div class="fusion-fullwidth fullwidth-box fusion-builder-row-11 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-82 fusion_builder_column_2_3 2_3 fusion-two-third fusion-column-first" style="--awb-bg-size:cover;width:66.666666666667%;width:calc(66.666666666667% - ( ( 4% ) * 0.66666666666667 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-71"><p><a href="http://prosurge.com">Surge Protective Devices</a> (SPD) are used to protect electrical equipment against surges (overvoltages) caused by lightning or switch of heavy duty machines (many people may ignore this). It may take some technical background when selecting a proper surge protective device as there are various technologies and regulations.</p>
<p>The IEC 61643 standard defines 3 types of surge protective devices for low voltage electrical system.</p>
<p>Type 1 or Class I: <a href="http://prosurge.com/din-rail-spd-ac-power-supply/">Type 1 SPD</a> can discharge strong lightning current and are installed in the main electrical switchboard when the building is protected with lightning protection system (lightning rod, down conductor and grounding).</p>
<p>Type 2 or Class II: These surge protective device (SPD) is designed to discharge current generated by indirect lightning hit which caused induced overvoltage on the power distribution network. Typically, they are installed at the main distribution switchboard. <a href="http://prosurge.com/type-2-spd-sp-series/">Type 2 SPD</a> are the most popular SPD on the market and Prosurge is offering them with different certificates.</p>
<p>Type 3 or Class III: Type 3 SPDs are designed to reduce the overvoltage at the terminals of sensitive equipment and therefore has a relative limited discharge current capacity.</p>
<p><strong>Where should SPD be installed?</strong></p>
<p><a href="http://prosurge.com/type-2-spd-sp-series/">Type 2 surge protective device</a> will be installed in the electrical installation’s incoming-end switchboard. If the distance between that surge protective device and the protected equipment exceeds 30 metres, an additional surge protective device (Type 2 or Type 3) should be installed near the equipment.</p>
<p><img decoding="async" src="http://engineering.electrical-equipment.org/wp-content/uploads/2009/10/Surge-Protection-Device-location.JPG" alt="Surge Protection Device location" /></p>
<p>When the building is protected by a lightning protection system, a <a href="http://prosurge.com/din-rail-spd-ac-power-supply/">Type 1 surge protective device</a> must be installed at the incoming end of the installation. Also, you can choose a Type 1+2 SPD or Type 1+2+3 SPD as they can further lower the overvoltage and save some cost in some cases.</p>
<p><img decoding="async" src="http://engineering.electrical-equipment.org/wp-content/uploads/2009/10/Surge-Protection-Device-location2.JPG" alt="Surge Protection Device location" /></p>
<p><strong>What discharge current is enough? Higher is better?</strong></p>
<p>For <a href="http://prosurge.com/din-rail-spd-ac-power-supply/">Type 1 surge protective devices</a>, the minimum requirement is a discharge capacity of Iimp = 12.5 kA (10/350). The typical discharge current capacity for <a href="http://prosurge.com/type-2-spd-sp-series/">Type 2 SPD</a> is 40kA. Note that higher discharge current not necessarily means better. It just mean that the SPD can endure more surges and thus can have a longer life time and thus required less replacement. Of course, it is at the cost of higher price : )</p>
<p><strong>How to coordinate a surge protective device with circuit breaker or fuse?</strong></p>
<p>It depends on the short circuit current that might happen at the installation location. Rule of thumb, for a residential electrical switchboard, a protection device with an Isc &lt; 6 kA will be chosen and for office applications, the Isc is generally &lt; 20 kA.</p>
<p>Of course, you can also check the SPD&#8217;s specification and installation. This information is required for choose a proper back up device.</p>
<p><img decoding="async" src="http://engineering.electrical-equipment.org/wp-content/uploads/2009/10/simplified-selection-principle.JPG" alt="simplified selection principle" /></p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-83 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-last" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-blog-shortcode fusion-blog-shortcode-1 fusion-blog-archive fusion-blog-layout-medium-alternate fusion-blog-infinite"><div class="fusion-posts-container fusion-posts-container-infinite fusion-posts-container-load-more fusion-no-meta-info fusion-blog-rollover" data-pages="8"><article id="blog-1-post-18666" class="fusion-post-medium-alternate post-18666 post type-post status-publish format-standard has-post-thumbnail hentry category-surge-protection-education">
<div class="fusion-date-and-formats"><div class="fusion-date-box updated"><span class="fusion-date">8</span><span class="fusion-month-year">08, 2025</span></div><div class="fusion-format-box"><i class="awb-icon-pen" aria-hidden="true"></i></div></div>	<style type="text/css">
		
		
		
		
			</style>


			<div class="fusion-flexslider flexslider fusion-flexslider-loading fusion-post-slideshow" style="">
		<ul class="slides">
			
														<li><div  class="fusion-image-wrapper fusion-image-size-fixed" aria-haspopup="true">
				<img decoding="async" width="320" height="202" src="https://prosurge.com/wp-content/uploads/2025/08/POSP-320x202.jpg" class="attachment-blog-medium size-blog-medium wp-post-image" alt="" srcset="https://prosurge.com/wp-content/uploads/2025/08/POSP-320x202.jpg 320w, https://prosurge.com/wp-content/uploads/2025/08/POSP-700x441.jpg 700w" sizes="(max-width: 320px) 100vw, 320px" /><div class="fusion-rollover">
	<div class="fusion-rollover-content">

														<a class="fusion-rollover-link" href="https://prosurge.com/posp-type1-plug-on-spd-whole-house-surge-protection/">Whole-House Surge Protection with Compact, UL Type 1 Plug-On SPD</a>
			
														
								
													<div class="fusion-rollover-sep"></div>
				
																		<a class="fusion-rollover-gallery" href="https://prosurge.com/wp-content/uploads/2025/08/POSP-scaled.jpg" data-options="" data-id="18666" data-rel="iLightbox[gallery]" data-title="POSP" data-caption="">
						Gallery					</a>
														
		
												<h4 class="fusion-rollover-title">
					<a class="fusion-rollover-title-link" href="https://prosurge.com/posp-type1-plug-on-spd-whole-house-surge-protection/">
						Whole-House Surge Protection with Compact, UL Type 1 Plug-On SPD					</a>
				</h4>
			
										<div class="fusion-rollover-categories"><a href="https://prosurge.com/category/surge-protection-education/" rel="tag">Surge Protection Education</a></div>					
		
						<a class="fusion-link-wrapper" href="https://prosurge.com/posp-type1-plug-on-spd-whole-house-surge-protection/" aria-label="Whole-House Surge Protection with Compact, UL Type 1 Plug-On SPD"></a>
	</div>
</div>
</div>
</li>
			
			
																																																																				</ul>
	</div>
	<div class="fusion-post-content post-content"><h2 class="blog-shortcode-post-title entry-title"><a href="https://prosurge.com/posp-type1-plug-on-spd-whole-house-surge-protection/">Whole-House Surge Protection with Compact, UL Type 1 Plug-On SPD</a></h2><div class="fusion-post-content-container"><p>Introduction Power surges — from lightning strikes, utility switching and upstream load events — cause costly [...]</p></div></div><div class="fusion-clearfix"></div></article>
<article id="blog-1-post-18648" class="fusion-post-medium-alternate post-18648 post type-post status-publish format-standard has-post-thumbnail hentry category-surge-protection-education">
<div class="fusion-date-and-formats"><div class="fusion-date-box updated"><span class="fusion-date">24</span><span class="fusion-month-year">07, 2025</span></div><div class="fusion-format-box"><i class="awb-icon-pen" aria-hidden="true"></i></div></div>	<style type="text/css">
		
		
		
		
			</style>


			<div class="fusion-flexslider flexslider fusion-flexslider-loading fusion-post-slideshow" style="">
		<ul class="slides">
			
														<li><div  class="fusion-image-wrapper fusion-image-size-fixed" aria-haspopup="true">
				<img decoding="async" width="320" height="202" src="https://prosurge.com/wp-content/uploads/2025/07/RJ45B-320x202.jpg" class="attachment-blog-medium size-blog-medium wp-post-image" alt="" srcset="https://prosurge.com/wp-content/uploads/2025/07/RJ45B-320x202.jpg 320w, https://prosurge.com/wp-content/uploads/2025/07/RJ45B-700x441.jpg 700w" sizes="(max-width: 320px) 100vw, 320px" /><div class="fusion-rollover">
	<div class="fusion-rollover-content">

														<a class="fusion-rollover-link" href="https://prosurge.com/from-cat6-to-poe-choosing-the-right-rj45-surge-protector-for-your-network/">From CAT6 to PoE: Choosing the Right RJ45 Surge Protector for Your Network</a>
			
														
								
													<div class="fusion-rollover-sep"></div>
				
																		<a class="fusion-rollover-gallery" href="https://prosurge.com/wp-content/uploads/2025/07/RJ45B.jpg" data-options="" data-id="18648" data-rel="iLightbox[gallery]" data-title="RJ45B" data-caption="">
						Gallery					</a>
														
		
												<h4 class="fusion-rollover-title">
					<a class="fusion-rollover-title-link" href="https://prosurge.com/from-cat6-to-poe-choosing-the-right-rj45-surge-protector-for-your-network/">
						From CAT6 to PoE: Choosing the Right RJ45 Surge Protector for Your Network					</a>
				</h4>
			
										<div class="fusion-rollover-categories"><a href="https://prosurge.com/category/surge-protection-education/" rel="tag">Surge Protection Education</a></div>					
		
						<a class="fusion-link-wrapper" href="https://prosurge.com/from-cat6-to-poe-choosing-the-right-rj45-surge-protector-for-your-network/" aria-label="From CAT6 to PoE: Choosing the Right RJ45 Surge Protector for Your Network"></a>
	</div>
</div>
</div>
</li>
			
			
																																																																				</ul>
	</div>
	<div class="fusion-post-content post-content"><h2 class="blog-shortcode-post-title entry-title"><a href="https://prosurge.com/from-cat6-to-poe-choosing-the-right-rj45-surge-protector-for-your-network/">From CAT6 to PoE: Choosing the Right RJ45 Surge Protector for Your Network</a></h2><div class="fusion-post-content-container"><p>In today’s hyper-connected world, safeguarding your data infrastructure is non-negotiable. An RJ45 surge protector is the first [...]</p></div></div><div class="fusion-clearfix"></div></article>
<article id="blog-1-post-18643" class="fusion-post-medium-alternate post-18643 post type-post status-publish format-standard has-post-thumbnail hentry category-surge-protection-education">
<div class="fusion-date-and-formats"><div class="fusion-date-box updated"><span class="fusion-date">11</span><span class="fusion-month-year">07, 2025</span></div><div class="fusion-format-box"><i class="awb-icon-pen" aria-hidden="true"></i></div></div>	<style type="text/css">
		
		
		
		
			</style>


			<div class="fusion-flexslider flexslider fusion-flexslider-loading fusion-post-slideshow" style="">
		<ul class="slides">
			
														<li><div  class="fusion-image-wrapper fusion-image-size-fixed" aria-haspopup="true">
				<img decoding="async" width="320" height="202" src="https://prosurge.com/wp-content/uploads/2025/07/IEC-61010-1-320x202.jpg" class="attachment-blog-medium size-blog-medium wp-post-image" alt="" /><div class="fusion-rollover">
	<div class="fusion-rollover-content">

														<a class="fusion-rollover-link" href="https://prosurge.com/decoding-the-new-benchmark-in-surge-protection-key-advancements-in-iec-61643-012024/">Decoding the New Benchmark in Surge Protection: Key Advancements in IEC 61643-01:2024</a>
			
														
								
													<div class="fusion-rollover-sep"></div>
				
																		<a class="fusion-rollover-gallery" href="https://prosurge.com/wp-content/uploads/2025/07/IEC-61010-1.jpg" data-options="" data-id="18643" data-rel="iLightbox[gallery]" data-title="IEC-61010-1" data-caption="">
						Gallery					</a>
														
		
												<h4 class="fusion-rollover-title">
					<a class="fusion-rollover-title-link" href="https://prosurge.com/decoding-the-new-benchmark-in-surge-protection-key-advancements-in-iec-61643-012024/">
						Decoding the New Benchmark in Surge Protection: Key Advancements in IEC 61643-01:2024					</a>
				</h4>
			
										<div class="fusion-rollover-categories"><a href="https://prosurge.com/category/surge-protection-education/" rel="tag">Surge Protection Education</a></div>					
		
						<a class="fusion-link-wrapper" href="https://prosurge.com/decoding-the-new-benchmark-in-surge-protection-key-advancements-in-iec-61643-012024/" aria-label="Decoding the New Benchmark in Surge Protection: Key Advancements in IEC 61643-01:2024"></a>
	</div>
</div>
</div>
</li>
			
			
																																																																				</ul>
	</div>
	<div class="fusion-post-content post-content"><h2 class="blog-shortcode-post-title entry-title"><a href="https://prosurge.com/decoding-the-new-benchmark-in-surge-protection-key-advancements-in-iec-61643-012024/">Decoding the New Benchmark in Surge Protection: Key Advancements in IEC 61643-01:2024</a></h2><div class="fusion-post-content-container"><p>Introduction: Surge Protective Devices (SPDs) serve as critical defense components in low-voltage electrical systems, safeguarding equipment [...]</p></div></div><div class="fusion-clearfix"></div></article>
<article id="blog-1-post-18613" class="fusion-post-medium-alternate post-18613 post type-post status-publish format-standard has-post-thumbnail hentry category-surge-protection-education">
<div class="fusion-date-and-formats"><div class="fusion-date-box updated"><span class="fusion-date">7</span><span class="fusion-month-year">07, 2025</span></div><div class="fusion-format-box"><i class="awb-icon-pen" aria-hidden="true"></i></div></div>	<style type="text/css">
		
		
		
		
			</style>


			<div class="fusion-flexslider flexslider fusion-flexslider-loading fusion-post-slideshow" style="">
		<ul class="slides">
			
														<li><div  class="fusion-image-wrapper fusion-image-size-fixed" aria-haspopup="true">
				<img decoding="async" width="320" height="202" src="https://prosurge.com/wp-content/uploads/2025/07/未标题-1-320x202.jpg" class="attachment-blog-medium size-blog-medium wp-post-image" alt="" srcset="https://prosurge.com/wp-content/uploads/2025/07/未标题-1-320x202.jpg 320w, https://prosurge.com/wp-content/uploads/2025/07/未标题-1-700x441.jpg 700w" sizes="(max-width: 320px) 100vw, 320px" /><div class="fusion-rollover">
	<div class="fusion-rollover-content">

														<a class="fusion-rollover-link" href="https://prosurge.com/leading-surge-protection-device-manufacturers-in-2025/">Leading Surge Protection Device Manufacturers in 2025</a>
			
														
								
													<div class="fusion-rollover-sep"></div>
				
																		<a class="fusion-rollover-gallery" href="https://prosurge.com/wp-content/uploads/2025/07/未标题-1-scaled.jpg" data-options="" data-id="18613" data-rel="iLightbox[gallery]" data-title="未标题-1" data-caption="">
						Gallery					</a>
														
		
												<h4 class="fusion-rollover-title">
					<a class="fusion-rollover-title-link" href="https://prosurge.com/leading-surge-protection-device-manufacturers-in-2025/">
						Leading Surge Protection Device Manufacturers in 2025					</a>
				</h4>
			
										<div class="fusion-rollover-categories"><a href="https://prosurge.com/category/surge-protection-education/" rel="tag">Surge Protection Education</a></div>					
		
						<a class="fusion-link-wrapper" href="https://prosurge.com/leading-surge-protection-device-manufacturers-in-2025/" aria-label="Leading Surge Protection Device Manufacturers in 2025"></a>
	</div>
</div>
</div>
</li>
			
			
																																																																				</ul>
	</div>
	<div class="fusion-post-content post-content"><h2 class="blog-shortcode-post-title entry-title"><a href="https://prosurge.com/leading-surge-protection-device-manufacturers-in-2025/">Leading Surge Protection Device Manufacturers in 2025</a></h2><div class="fusion-post-content-container"><p>Surge Protection Devices (SPDs) are vital components in safeguarding electrical installations—whether in industrial plants, commercial buildings, [...]</p></div></div><div class="fusion-clearfix"></div></article>
<article id="blog-1-post-18536" class="fusion-post-medium-alternate post-18536 post type-post status-publish format-standard has-post-thumbnail hentry category-surge-protection-education">
<div class="fusion-date-and-formats"><div class="fusion-date-box updated"><span class="fusion-date">6</span><span class="fusion-month-year">06, 2025</span></div><div class="fusion-format-box"><i class="awb-icon-pen" aria-hidden="true"></i></div></div>	<style type="text/css">
		
		
		
		
			</style>


			<div class="fusion-flexslider flexslider fusion-flexslider-loading fusion-post-slideshow" style="">
		<ul class="slides">
			
														<li><div  class="fusion-image-wrapper fusion-image-size-fixed" aria-haspopup="true">
				<img decoding="async" width="320" height="202" src="https://prosurge.com/wp-content/uploads/2025/06/图片3-320x202.png" class="attachment-blog-medium size-blog-medium wp-post-image" alt="" srcset="https://prosurge.com/wp-content/uploads/2025/06/图片3-320x202.png 320w, https://prosurge.com/wp-content/uploads/2025/06/图片3-700x441.png 700w" sizes="(max-width: 320px) 100vw, 320px" /><div class="fusion-rollover">
	<div class="fusion-rollover-content">

														<a class="fusion-rollover-link" href="https://prosurge.com/which-surge-protection-devices-is-better-prosurges-surge-protection-devices-with-vt-technology/">Which Surge protection devices is better? &#8212;&#8211;Prosurge’s Class I + Class II/T1+T2 Surge protection devices with VT technology</a>
			
														
								
													<div class="fusion-rollover-sep"></div>
				
																		<a class="fusion-rollover-gallery" href="https://prosurge.com/wp-content/uploads/2025/06/图片3.png" data-options="" data-id="18536" data-rel="iLightbox[gallery]" data-title="图片3" data-caption="">
						Gallery					</a>
														
		
												<h4 class="fusion-rollover-title">
					<a class="fusion-rollover-title-link" href="https://prosurge.com/which-surge-protection-devices-is-better-prosurges-surge-protection-devices-with-vt-technology/">
						Which Surge protection devices is better? &#8212;&#8211;Prosurge’s Class I + Class II/T1+T2 Surge protection devices with VT technology					</a>
				</h4>
			
										<div class="fusion-rollover-categories"><a href="https://prosurge.com/category/surge-protection-education/" rel="tag">Surge Protection Education</a></div>					
		
						<a class="fusion-link-wrapper" href="https://prosurge.com/which-surge-protection-devices-is-better-prosurges-surge-protection-devices-with-vt-technology/" aria-label="Which Surge protection devices is better? &#8212;&#8211;Prosurge’s Class I + Class II/T1+T2 Surge protection devices with VT technology"></a>
	</div>
</div>
</div>
</li>
			
			
																																																																				</ul>
	</div>
	<div class="fusion-post-content post-content"><h2 class="blog-shortcode-post-title entry-title"><a href="https://prosurge.com/which-surge-protection-devices-is-better-prosurges-surge-protection-devices-with-vt-technology/">Which Surge protection devices is better? &#8212;&#8211;Prosurge’s Class I + Class II/T1+T2 Surge protection devices with VT technology</a></h2><div class="fusion-post-content-container"><p>What Is a Surge Protection Device (SPD)? A surge protector—also known as a surge protection device [...]</p></div></div><div class="fusion-clearfix"></div></article>
<article id="blog-1-post-18533" class="fusion-post-medium-alternate post-18533 post type-post status-publish format-standard has-post-thumbnail hentry category-surge-protection-education">
<div class="fusion-date-and-formats"><div class="fusion-date-box updated"><span class="fusion-date">30</span><span class="fusion-month-year">05, 2025</span></div><div class="fusion-format-box"><i class="awb-icon-pen" aria-hidden="true"></i></div></div>	<style type="text/css">
		
		
		
		
			</style>


			<div class="fusion-flexslider flexslider fusion-flexslider-loading fusion-post-slideshow" style="">
		<ul class="slides">
			
														<li><div  class="fusion-image-wrapper fusion-image-size-fixed" aria-haspopup="true">
				<img decoding="async" width="250" height="202" src="https://prosurge.com/wp-content/uploads/2023/03/KEMA-250x202.jpg" class="attachment-blog-medium size-blog-medium wp-post-image" alt="" srcset="https://prosurge.com/wp-content/uploads/2023/03/KEMA-177x142.jpg 177w, https://prosurge.com/wp-content/uploads/2023/03/KEMA-250x202.jpg 250w" sizes="(max-width: 250px) 100vw, 250px" /><div class="fusion-rollover">
	<div class="fusion-rollover-content">

														<a class="fusion-rollover-link" href="https://prosurge.com/about-surge-protective-devices-standard-iec-en-61643/">Ensuring Reliable Surge Protection with IEC/EN 61643 and IEC/EN 62305 Standards</a>
			
														
								
													<div class="fusion-rollover-sep"></div>
				
																		<a class="fusion-rollover-gallery" href="https://prosurge.com/wp-content/uploads/2023/03/KEMA.jpg" data-options="" data-id="18533" data-rel="iLightbox[gallery]" data-title="KEMA" data-caption="">
						Gallery					</a>
														
		
												<h4 class="fusion-rollover-title">
					<a class="fusion-rollover-title-link" href="https://prosurge.com/about-surge-protective-devices-standard-iec-en-61643/">
						Ensuring Reliable Surge Protection with IEC/EN 61643 and IEC/EN 62305 Standards					</a>
				</h4>
			
										<div class="fusion-rollover-categories"><a href="https://prosurge.com/category/surge-protection-education/" rel="tag">Surge Protection Education</a></div>					
		
						<a class="fusion-link-wrapper" href="https://prosurge.com/about-surge-protective-devices-standard-iec-en-61643/" aria-label="Ensuring Reliable Surge Protection with IEC/EN 61643 and IEC/EN 62305 Standards"></a>
	</div>
</div>
</div>
</li>
			
			
																																																																				</ul>
	</div>
	<div class="fusion-post-content post-content"><h2 class="blog-shortcode-post-title entry-title"><a href="https://prosurge.com/about-surge-protective-devices-standard-iec-en-61643/">Ensuring Reliable Surge Protection with IEC/EN 61643 and IEC/EN 62305 Standards</a></h2><div class="fusion-post-content-container"><p>In today’s rapidly evolving electrical and renewable energy landscapes, selecting the right surge protective devices (SPDs) [...]</p></div></div><div class="fusion-clearfix"></div></article>
</div><div class="fusion-infinite-scroll-trigger"></div><div class="pagination infinite-scroll clearfix" style="display:none;"><span class="current">1</span><a href="https://prosurge.com/tag/surge-protection-device/feed/page/2/" class="inactive">2</a><a class="pagination-next" rel="next" href="https://prosurge.com/tag/surge-protection-device/feed/page/2/"><span class="page-text">Next</span><span class="page-next"></span></a></div><div class="fusion-clearfix"></div><button class="fusion-load-more-button fusion-blog-button fusion-clearfix">Load More Posts</button></div><div class="fusion-clearfix"></div></div></div>
</div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-12 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"></div></div></p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
