PSP E series

surge capacity: 25~50kA per phase

Nominal discharge current:10kA

PSP B series

surge capacity: 50kA per phase

Nominal discharge current:10kA

20PSP B series

surge capacity: 100kA per phase

Nominal discharge current:20kA

PSP F series

surge capacity: 50kA per phase

Nominal discharge current:20kA

PSP C1 series

surge capacity: 100~300kA per phase

Nominal discharge current:20kA

PSP C2 series

surge capacity: 100~300kA per phase

Nominal discharge current:20kA

HPSP series

surge capacity: 400~600kA per phase

Nominal discharge current:20kA

The PSP series panel SPD is built around Prosurge’s patented PTMOV, which integrates thermal protection and arc extinguishing technology – the core of Prosurge’s expertise. This gives the PSP panel SPD a distinct advantage in handling abnormal over-voltage and high fault current scenarios, ensuring the highest level of safety and performance in the industry. Its parallel redundancy module design enhances robustness and reliability, enabling the SPD to withstand massive surge currents as well as repeated impulses at its maximum rated level.

Features:

• UL Listed Type 1 (ANSI/UL1449 5th, CSA C22.2) SPDs
• UL Listed Type 2 (ANSI/UL1449 5th, CSA C22.2) SPDs with sine wave tracking
• Prosurge patented SCCR 200kArms thermally protected MOV technology (PTMOV/20PTMOV) as key component
• Full modes protection & High surge energy capability in compact size
• Sine wave tracking function optional (for UL Type 2 listed model, UL1283 listed EMI/RFI filter for C series)
• Low voltage protection rating
• Waterproof plastic/metal enclosure to resist dirt, dust and water
• Failure indication
• Surge event counter optional
• Floating changeover contact for remote alarm
• Threaded NPT

Configuration & Ordering information:

PSP

Model series

277Y

Voltage and system configuration

C

Protection mode

42

Surge capacity

M

Enclosure

T1

SPD Category

CTA

Additional function

PSP

120SP: 120/240V split

240SP:240/480V split

120Y:120/1208V WYE

277Y: 277/480V WYE

120H: 120/240V high leg delta

240D: 240V delta

120S:120V 1ph, 2W+G

C: Delete N-G protection mode

11: 25kA per phase

12:50kA per phase

22:100kA per phase

32:150kA per phase

42:200kA per phase

52:250kA per phase

62:300kA per phase

M: metal enclosure

(Only C2 type)

*Part No. without  M means plastic enclosure

(E, B, C1 type)

T1: UL type 1 SPD

T2F: UL type 2 SPD with sine wave tracking

 

C: surge event counter

T: Failure pretest

A: remote alarm